Selecting one or more of the checkboxes direct-
ly to the right of the Clear All button and clicking
the Clear All button clears all selected check-
boxes in that column. Similarly, clicking the Set
All button sets all checkboxes in the column
checked next to the buttons. Only named regis-
ters may be checked or unchecked; unnamed
registers are assumed to be unused. After a Set
All or Clear All command, any checkboxes may
be individually selected or deselected as nee-
ded.
Include
Time/
Date Per
Record
Select the Include time/date per record check-
box to include a time and date stamp for each
record logged to the log files.
Prev
and
Next
Scrolls through the registers of the device listed
to the left of the Showing box.
Up-
date
Clicking the Update button sends information to
the Ethernet Bridge or GatewayPro or retrieves
information depending on which checkboxes are
selected: Change or Get/Send All. Updating infor-
mation does not save configuration information
permanently to the XML file.
Events Logged
Use the Events Logged page to select which events are logged to a file.
Events are established in the list of rules found in System > Action Rules > Thresholds tab. Use the Thresholds page to establish the test
criteria that defines true and false. It is not necessary to set a destination register to any particular value in a threshold rule.
The result records to the event logger regardless of any other action taken as a result of the action or threshold rule. The list shown on
this page reflects the defined threshold rules.
Event records are stored in a CSV format text file. Each record includes time/date, event number, and true/false active state. If the Ver-
bose Log checkbox is selected, the records also include the event name string, register number, register value, test type, and test value.
Prev
and
Next
Scrolls through the threshold events established
on the System > Action Rules > Thresholds, Ex-
panded View page.
Up-
date
Clicking the Update button sends information to
the Ethernet Bridge or GatewayPro or retrieves
information depending on which checkboxes are
selected: Change or Get/Send All. Updating infor-
mation does not save configuration information
permanently to the XML file.
Verbose
Log
Selecting a Verbose log sets the records to in-
clude the event name string, register number,
register value, test type, and test value.