User Manual

Configurable Node with 2 selectable counter inputs, 2 selectable discrete inputs, and 2 NMOS discrete outputs
IP67 Base
2.4 GHz
IP20 Base
900 MHz
The SureCross® wireless system is a radio frequency network with integrated I/O that can oper-
ate in most environments and eliminate the need for wiring runs. Wireless networks are formed
around a Gateway, which acts as the wireless network master device, and one or more Nodes.
Wireless industrial I/O device with two selectable discrete inputs, two selectable discrete pulse
counter inputs (rate or event; sinking, sourcing, or self-energized), and two NMOS discrete
outputs
User selectable 10 kHz event counter(s) and/or 25 kHz rate counter
FlexPower® power options allows for +10 to 30V dc, solar, and battery power sources for low
power applications.
DIP switches for user configuration
Frequency Hopping Spread Spectrum (FHSS) technology and Time Division Multiple Access
(TDMA) control architecture ensure reliable data delivery within the unlicensed Industrial, Sci-
entific, and Medical (ISM) band
Transceivers provide bidirectional communication between the Gateway and Node, including
fully acknowledged data transmission
Lost RF links are detected and relevant outputs set to user-defined conditions
The DX80...C models are certified for use in Class I, Division 2, Group A, B, C, D; Zone 2
(Category 3G) Hazardous Locations when properly installed in accordance with the National
Electrical Code, the Canadian Electrical Code, or applicable local codes/regulations (see
Specifications)
For additional information, updated documentation, and accessories, refer to Banner Engineering's website, www.bannerengineer-
ing.com/surecross.
Models Frequency Environmental Rating I/O
DX80N9X2S4A2 900 MHz ISM Band
IP67, NEMA 6
Inputs: Two selectable discrete, two se-
lectable counter
Outputs: Two NMOS sinking discrete
DX80N2X2S4A2 2.4 GHz ISM Band
DX80N9X2S4A2C 900 MHz ISM Band IP20, NEMA 1
Class I, Division 2, Group A, B, C, D Haz-
ardous Locations (see Specifications)
DX80N2X2S4A2C 2.4 GHz ISM Band
Internal antenna models are also available. For more information, contact your local Banner Engineering Corp. representative.
WARNING: Not To Be Used for Personnel Protection
Never use this device as a sensing device for personnel protection. Doing so could lead to serious
injury or death. This device does not include the self-checking redundant circuitry necessary to allow its
use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-
energized sensor output condition.
SureCross User Configuration Tool
The User Configuration Tool (UCT) offers an easy way to link I/O points in your wire-
less network, view I/O register values graphically, and set system communication pa-
rameters when a host system is not part of the wireless network.
The UCT requires a special USB to RS-485 (model number BWA-UCT-900 for 1 Watt
radios, BWA-HW-006 can be used for all other radios) converter cable to pass infor-
mation between your computer and the Gateway. Download the most recent revi-
sions of the UCT software from Banner Engineering's website: http://www.banneren-
gineering.com/wireless.
SureCross DX80 FlexPower Counter Node
P/N 136348 Rev. G 5/22/2013
0 136348 7