Manual

Printed in USA 10/04 P/N 116164
Installation
Guide
T18 Sensors ac-Voltage Series
Self-contained, ac-operated sensors
51.5 mm
(2.03")
ø 40.0 mm
(1.57")
Jam Nut
(Supplied)
11.5 mm
(0.45")
M18 x 1
Thread
ø 15 mm
(0.59")
30.0 mm
(1.18")
Green LED
Power Indicator
Yellow LED
Output Indicator
* Standard 2 m (6.5') cable models are listed.
9 m (30') cable: add suffix “W/30” (e.g., T183E W/30).
4-pin Micro-style QD models: add suffix “Q1” (e.g., T183EQ1). A model with a QD connector
requires a mating cable.
Use polarized models when shiny objects will be sensed.
WARNING . . .
Not To Be Used for Personnel Protection
Never use these products as sensing devices for personnel protection. Doing so could lead to serious injury or death.
These sensors do NOT include the self-checking redundant circuitry necessary to allow their use in personnel safety
applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition.
Consult your current Banner Safety Products catalog for safety products which meet OSHA, ANSI and IEC standards for
personnel protection.
!
Additional information on this product is immediately available online at www.bannerengineering.com/116164
View or download additional information, including excess gain curves, beam patterns and accessories.
For further assistance, contact a Banner Engineering Applications Engineer at (763) 544-3164 or (888) 373-6767.
Dimensions
LISTED
R
Cabled Models
QD Models
Sensing Mode Range LED Output Model*
Opposed
20 m
(66')
Infrared
950 nm
T183E
LO
T18AW3R
DO
T18RW3R
Retro-
reflective
with Gain control
2 m
(79")
LO
T18AW3L
DO
T18RW3L
Polarized
Retro-
reflective
Visible
Red
680 nm
LO
T18AW3LP
DO
T18RW3LP
Diffuse
with Gain control
300 mm
(12")
Infrared
880 nm
LO
T18AW3D
DO
T18RW3D
Fixed
Field
25 mm (1")
cutoff
LO
T18AW3FF25
DO
T18RW3FF25
50 mm (2")
cutoff
LO
T18AW3FF50
DO
T18RW3FF50
100 mm (4")
cutoff
LO
T18AW3FF100
DO
T18RW3FF100
P
66.5 mm
(2.62")
ø 40.0 mm
(1.57")
Single-turn
Sensitivity (Gain) Control
(D and L Models)
bn
bu
bk
20-250V ac
Load
Cabled Emitters
20-250V ac
No Connection
rd/wh
rd/bk
rd
gn
bn
bu
20-250V ac
All Other Cabled Models
QD Emitters
(4-pin Micro-Style)
All Other QD Models
(4-pin Micro-Style)
20-250V ac
No Connection
Load
rd/wh
rd
rd/bk
gn

Summary of content (2 pages)