cords from sharp objects, excessive heat and damp or wet areas.
Grounded tools require a 3-wire extension cord. Double Insulated tools can use either a 2- or 3-
wire extension cord.
As the distance from the supply outlet increases, you must use a heavier gauge extension cord.
Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in
loss of power and possible tool damage.
The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a
14-gauge cord can carry a higher current than a 16-gauge cord. Minimum extension cord wire
size is shown in the following table:
Minimum Wire Size Of Extension Cords
Nameplate AMPS
Cord Length
25'
50'
100'
150'
0-6
18 AWG
16 AWG
16 AWG
14 AWG
6-10
18 AWG
16 AWG
14 AWG
12 AWG
10-12
16 AWG
16 AWG
14 AWG
12 AWG
12-16
14 AWG
12 AWG
NOT RECOMMENDED
When using more than one extension cord to make up the total length, make sure each cord
contains at least the minimum wire size required.
If you are using one extension cord for more than one tool, add the nameplate amperes and use
the sum to determine the required minimum cord size.
If you are using an extension cord in damp locations, make sure it is marked with the suffix W-A
(W in Canada) to indicate it is acceptable for outdoor use.
Make sure your extension cord is properly wired and in good electrical condition. Always replace
a damaged extension cord or have it repaired by a qualified electrician before using it.
Protect your extension cords from sharp objects, excessive heat, and damp or wet areas.
Before Each Use
WARNING
Be sure parts are not damaged.
Be sure all parts are secure.
Operating Instructions
WARNING
Electric shock hazard. Do not expose to water or rain. Never place blower in standing water.
Be sure equipment is properly grounded.
Use only outdoor-rated extension cords of proper size.
Do not use this product with any solid-state speed control device.
Rotating Blade Hazard. Can cause serious injury or cut. Keep hands clear.
For indoor use only. Do not use outdoors. Do not place the fan in or near a window. Rain may
create an electrical hazard.