Owner`s manual

109220-01C
4
INSTALLATION
WARNING: Before installing in a solid fuel burn-
ing fireplace, the chimney flue and firebox must be
cleaned of soot, creosote, ashes and loose paint by
a qualified chimney cleaner. Creosote will ignite if
highly heated. A dirty chimney flue may create and
distribute soot within the house. Inspect chimney
flue for damage.
NOTICE: Installation, service, and repair of this appli-
ance must be performed by a qualified installer, ser-
vice agency, company or gas supplier experienced
with this type of gas appliance. Only factory autho-
rized components listed in these instructions may be
used in accordance with the manufacturers instruc-
tions and all codes and requirements of the authority
having jurisdiction. Any modifications to this kit, or
use of unauthorized components or accessory items
will void the manufacturers warranty, and may result
in a hazardous condition.
CAUTION: Do not remove the data plates at-
tached to the burner pan. The data plates contain
important warranty information.
FLUE OPENING SPECIFICATIONS
Note:
This vented appliance must be installed only in a solid-fuel
burning fireplace with a working flue and constructed of noncom-
bustible material.
The charts in Figure 2 indicate technical information regarding the
installation of your gas log set. Please make sure that all of the
specifications shown are applicable before installation is attempted.
The fireplace must include a working flue and venting system with
the minimum openings shown in the Figure 2. The minimum flue
sizes shown in Figure 2 are based on a 6' chimney height using round
pipe. Your minimum flue size will vary based on input rate and
chimney height. Refer to the National Fuel Gas Code ANSI Z233.1/
NFPA 54, Section 6.6, for details
MODEL DESCRIPTION
BVDA18M 18" Dual Burner
55,000 45,000 .116 32 .082 45
BVDA24M 24" Dual Burner
65,000 55,000 .138 29 .086 44
BVDA30M 30" Dual Burner
70,000 60,000
.1405
28 .089 43
Btu Input
Natural
Gas
Btu Input
Propane/
LP Gas
MINIMUM FIREBOX SIZES
LOG FRONT BACK MINIMUM
SIZE WIDTH WIDTH* DEPTH HEIGHT
FLUE SIZE
18" 34" 16" 14" 18" 8" diam.
24" 35
3
/4" 17" 15
1
/2" 18" 8" diam.
30" 42" 27" 18" 18" 9" diam.
*At depth indicated
SPECIFICATIONS (W.C.)
Min. Max.
NG 7 10.5 6
LP 11 14 10
Figure 2 - Technical Information Charts
Burner Orifice
Natural
Propane/LP
In.
Num.
In.
Num.
CHECK GAS TYPE
Use only natural gas. If your gas supply is not natural gas, you must
convert the appliance to Propane/LP. Follow the instructions on
page 7.
If the fireplace does not have a gas supply shut-off valve, one must
be installed.
FUEL INLET PRESSURE MANIFOLD PRESSURE
INSTALLATION
Flue Opening Specifications
Check Gas Type
WARNING: The Massachusetts State Board re-
quires all installations be performed by a Licensed
Plumber or Gas Fitter. Massachusetts state code re-
quires all vent dampers be welded open or removed.