Brochure

TK-1xxx Series, TKR-1xxx Series
138
© Copyright 2006 TAC. All Rights Reserved. F-27383-1
Figure 3 Options (for quantities of 24 or more of each part number).
Add dash number (-xxx) suffix to base part number for desired option.
For metal covers, specify TK2-xxxx-xxx.
Specifications
Thermostat Proportional type.
Sensing element Bimetal.
Night setback To 20qF (11qC) below day setpoint for Day/Night heating models.
Night setup To 20qF (11qC) above day setpoint for Day/Night cooling models.
Control dial range Refer to Model Chart.
Throttling Range
TK-1xx1, TKR-1xx1 Adjustable 2 to 10qF/10 psi, factory set at 4qF/10 psi.
Output air signal 0.5 psig to supply air pressure -0.5 psig.
Action Refer to Model Chart.
Ambient limits
Shipping -40 to 150qF (-40 to 65qC). 0 to 98% RH, non-condensing.
Operating 40 to 150qF (4 to 65qC). 10 to 98% RH, non-condensing.
Supply air pressure Clean, oil free, dry air required (reference EN-123).
Nominal Refer to Model Chart.
Maximum 30 psig (207 kPa).
Air connections
Main (black) 5/32 in. dia. spring reinforced plastic tube.
Branch (white) 5/32 in. dia. spring reinforced plastic tube.
Air consumption for sizing air compressor
TK/TKR-1001, 1001-116, 1101,
1101-116, 12x1, 13x1, TK-1301-116
13.8 scim (3.8 mL/s).
TK-1001-600, 1101-600, 16x1-116,
TK/TKR-16x1
41.5 scim (11.3 mL/s).
Air capacity for sizing air mains
TK/TKR-1001, 1001-116, 1101,
1101-116, 13x1, 1301-116
16 scim (4.4 mL/s).
TK-1001-600, 1101-600 56 scim (15.3 mL/s).
TK/TKR-13x1, 12x1, TK-1301-116 80 scim (21.8 mL/s).
TK/TKR-16x1 104 scim (28.4 mL/s).
TK/TKR-16x1-116 144 scim (39.3 mL/s).
Cover
Beige plastic as standard except aspirated versions. Aspirated units have brushed stainless
steel covers.
Mounting Upright position on wall.
F -399
C -398
-400
-410
†† 5/64 in. Allen screw used to secure cover.
-403††
-413††
-404††