Specifications

2. System Overview
On the inside of the control panel there can be found:
2 x relay 12V/30A for guarding oil pressure and temperature of cooling liquid with aid of a stopping coil (Engine shuts off when
the oil pressure is low or the temperature of the cooling liquid is to high).
1 x relay 12V/30A by-pass guards (oil pressure) when starting engine.
2.5.4 Starting and using the generator
CAUTION: The generato r 183TDE is equipped with a 12V electric fuel pump. This pump may not “run dry”. If
the engine stops because it is out of fuel, turn the contact key to position “OFF ” as fast as possible.
Starting the engine
1. Check the oil level. Oil dipstick can be reached through the plastic cover on top of the generating set
Image 2-10
Oil level check
2. Check the fuel level, add if necessary .
Image 2-11
Fuel check
Caution: Adding fuel with engine stopped a nd in a sufficiently ventilated room, respecting the necessary personal safety pre-
cautions.
3. Preheat the engine for approximately 10 sec.
4. Start the engine with the starting key.
Image 2-12
5. Let the engine run for a few minutes before charging.
Charging the generator
1. On the type indication plate of the ge
nerator you can find more information about the power/maximum admissible charging current
of the generator.
R5976956 B-10 MOBILE LED 19/06/2007