Specifications
Table Of Contents

4. Maintenance, Service
Daily 500 km
Quarterly
Yearly
C
L
T
Cl C
L
T
Cl C
L
T
Cl C
L
T
Cl
cylinder flexible
attachment to grid
Generator
general
motor
alternator
oil
gas - diesel
exhausts
fixing
state
C = Control
L = Lubricate
T = Tighten
Cl = Clean
After 50h 00 the diesel g enerator need s to get its first mainten ance. Please refer to the Kubota and Leroy
Somer manuals as well as section 4.2 for m ore info rmation on maintenance of t he generator.
Used oil in t he B-10 Mobile LED
Oil used in the generator is 10 W 40 f or ambient temperature up to -20°C.
Hydraulic o il is SAE 3 5
4.2 Service and Maintenance of the Generator
Parts
The B-10 Mobile LED is equipped with a diesel-fueled generator. The generator is composed of a diesel motor from Kubota (KUB-
OTA D1105) and an alte
rnator from Leroy Somer (LSA 37M8).
Alternator
The alternators are maintenance-free. A periodic check of the alternator is not necessary. A regular visual control of the different
alternator parts – and especially of the rotor bearing – at every engine maintenance is enough.
Engine
Check engine manual for maintenance intervals.
Below you will find a list of official service centres for the Kubota and Leroy Somer components. Please refer to their respective
manual for more detail on these components and their maintenance.
CAUTION: The diesel generator needs after 50h00 its first maintenance run.
Remarks
In the factory, the radiator has been filled with coolant for use up to -15°C.
The engine has been filled in the factory with 10W40 oil (up to -20°C). If a lower temperature is needed, fill with 5W40 oil (up to
-30°C).
R5976956 B-10 MOBILE LED 19/06/2007