Instruction manual

ScreenPRO-II Controller • Users Guide 131
4. Menu Orientation
System Menu
i~åíêçåáñ=pÉíìé=jÉåì
On the Router Specification Menu, when Communication Type is set to LANTRONIX,
press
{COMM SETUP} to display the Lantronix Setup Menu:
Figure 4-33. Lantronix Setup Menu (sample)
The Lantronix Setup Menu enables you to set parameters for multiple Lantronix Ethernet-
to-Serial device servers. The ScreenPRO-II Controller supports Lantronix models
UDS100
and
UDS200. The menu will appear blank until the Lantronix device is “discovered.”
Number — selects the number of the Lantronix device that you wish to set up.
Press {DISCOVER LTRX} to set up communications with the Lantronix device.
Channel — sets the specific Lantronix channel (1 or 2) that you wish to set up.
Each Lantronix can control two serial routers.
Baud Rate — sets the selected channel’s baud rate.
Data Bits — sets the selected channel’s data bits.
Stop Bit — sets the selected channel’s stop bit.
Parity — sets the selected channel’s parity.
IP — displays the IP address of the Lantronix. This parameter must be set at the
device itself.
MAC Addr — displays the hard-coded MAC address of the Lantronix.
B
A
C
K
N
A
V
A
D
J
LANTRONIX SETUP
Number < EMPTY >
[ N/A ]Channel
[ N/A ]Baud rate
[ N/A ]Data bits
DISCOVER
LTRX
[ N/A ]Stop bit
[ N/A ]Parity
IP: N/A
MAC Addr: [ N/A ]
Important
Prior to pressing {DISCOVER LTRX}, it is highly
recommended that you set up a static IP address on the
Lantronix device itself. The recommended range is
192.168.0.200 - 192.168.0.239 — such as not to conflict with
other devices in the ScreenPRO-II Controller system. Refer
to the
Lantronix UDS100 or UDS200 Users Guide for
instructions.