Coronis Fusion 4MP/6MP User Guide
Coronis Fusion 4MP/6MP
Welcome! Thank you for choosing this CORONIS FUSION 4MP/6MP display! Coronis Fusion is an ingenious PACS display system designed to further enhance flexibility and productivity in diagnostic imaging. Featuring the industry’s first 30-inch color LCD that can be used as two seamless heads or one wide-screen display, Coronis Fusion offers you the freedom to organize your workspace just the way you want it.
Coronis Fusion 4MP/6MP
Table of contents Welcome!.........................................................................3 Table of contents .............................................................5 What's in the box.............................................................7 Parts, controls and connectors ........................................8 Front view ............................................................................................... 8 Rear view ..........................................................
Display Function menu................................................................. 31 Settings menu ............................................................................... 36 Information menu......................................................................... 38 Changing the viewing mode ............................................................... 39 Enabling/disabling User Controls........................................................ 39 Switching Power LED on/off ....................
What's in the box Your CORONIS FUSION 4MP/6MP display comes with: • this CORONIS FUSION 4MP/6MP display guide • a system CD • two DVI cables • a USB cable • a set of AC power cords • an external power supply If you ordered a Barco display controller, it’s also in the box together with its accessories. A dedicated user guide is available on the system CD. Keep your original packaging. It is designed for this display and is the ideal protection during transport.
Parts, controls and connectors Front view 1 8 2 3 4 5 6 7 8 1 USB downstream connectors 2 Left/Down key 3 Right/Up key 4 Enter key 5 Stand-by key 6 Ambient light sensor 7 Power status indicator light 8 Control wheel Coronis Fusion 4MP/6MP
Rear view 1 1 Connector compartment cover 3 Display stand cover 2 2 3 Neck cover Coronis Fusion 4MP/6MP 9
CORONIS FUSION 4MP 1 2 3 4 5 6 7 1 +24 VDC power input 2 USB upstream connector 3 USB downstream connector 4 +5 VDC, 0.25 A power output for accessories 5 +3.3 VDC, 0.
CORONIS FUSION 6MP 1 2 3 4 5 6 7 1 +24 VDC power input 2 USB upstream connector 3 USB downstream connector 4 +5 VDC, 0.25 A power output for accessories 5 +3.3 VDC, 0.
Display installation Prior to installing your CORONIS FUSION 4MP/6MP display and connecting all necessary cables, make sure to have a suitable display controller physically installed in your computer. If you are using a Barco display controller, please consult the dedicated user guide available on the system CD. Removing the covers CONNECTOR COMPARTMENT COVER The connector compartment cover should be removed to get access to the connectors.
DISPLAY STAND COVER To get access to the cable routing channel, the display stand cover should be removed. This can be done as follows: 1 Gently press and hold the clips at the inside top of the cover. 2 Slide the cover upwards while holding the clips pressed.
Unlocking the height mechanism In the factory, the height-positioning system in the display stand is locked with a red hook to prevent damage during transportation. You’ll have to remove this hook before adjusting your display height position. 1 While holding the display panel pushed down, pull out the red hook in the display stand. To retain the hook for possible future transportation, insert the short, red end of the hook back into the stand of your display.
Adjusting the display position Now that the height-positioning system of your display is unlocked, you can tilt, swivel, raise and lower the display as desired. Do not try to pivot your display when attached to the stand. Trying to do so could cause serious damage to your display and its stand.
Connecting the signal cables 1 Connect one head of the display controller to the DVI 1 connector with one of the supplied DVI cables. 2 Connect another head of the display controller to the DVI 2 connector with one of the supplied DVI cables. 3 If you want to make use of your display’s USB downstream connectors, connect a PC USB downstream connector to the display’s USB upstream connector by means of the supplied USB 2.0 cable.
Connecting the power cables 1 Connect the supplied external DC power supply to the +24 VDC power input of your CORONIS FUSION 4MP/6MP display. 2 Plug the other end of the external DC power supply into a grounded power outlet by means of the proper power cord delivered in the packaging. Routing the cables Route all connected cables trough the cable routing channel in the stand of your display.
Re-attaching the covers 1 Re-attach the display stand cover by sliding it downward. You’ll hear a “click” sound of the cover’s clips when the display stand cover is in position. Pay attention that all cables stay in the cable channel while replacing the cover. 2 Re-attach the connector compartment cover by sliding the cover’s top in position and then push the cover’s bottom. You’ll hear a “click” sound of the cover’s clips when the connector compartment cover is in position.
VESA-mount installation The panel, standard attached to a stand, is compatible with the VESA 100 mm standard. Thus, it can be used with an arm that is approved by VESA. This chapter shows you how to release the panel from the stand and how to attach it to an arm. If you’re not using an arm, you can skip this chapter. 1 Gently pull open both lower sides of the cover. 2 Slide the cover upwards while holding the lower sides pulled open.
3 Lift the plastic frame that covers the fixation of the panel to the stand. Turn it for 45 degrees to uncover the fixation screws. 4 Unscrew the four fixation screws fixing the panel to the stand. 5 Attach the panel firmly to the arm using 4 screws M4 x 10 mm. You should mount the panel in landscape position. Portrait position is possible but not supported. Use an arm that can support a weight of at least 21.6 kg (47.62 lbs).
First time starting up You are now ready to start up your CORONIS FUSION 4MP/6MP display system for the first time. 1 Switch on your CORONIS FUSION 4MP/6MP display as described in “Stand-by switching” on page 24. 2 Turn on the computer connected to your display. If you have properly installed your display and display controller, the Windows start-up messages will appear once the boot procedure is finished.
Daily operation Recommendations for daily operation OPTIMIZE THE LIFETIME OF YOUR DISPLAY Enabling the Display Power Management System (DPMS) of your display will optimize its diagnostic lifetime by automatically switching off the backlight when the display is not used for a specified period of time. By default, DPMS is enabled on your display, but it also needs to be activated on your workstation. To do this, go to “Power Options Properties” in the “Control Panel”.
performance of the product. To ensure optimal product quality, Barco applies strict selection criteria for its LCD panels. To learn more about LCD technology and missing pixels, consult the dedicated white papers available at www.barco.com/ medical. ENHANCE USER COMFORT Every Barco multi-head display system is color matched with the highest specification in the market. Barco recommends keeping color-matched displays together.
Stand-by switching The connected power supply also provides a switch that can be used to turn the power completely off. To use the display, please make sure to switch on this power supply. This can be done by pushing the on/off switch on the power supply into the "|" position. USING THE TOUCH KEYS: 1 While the OSD is not on the screen, touch any touch key. As a result, the control panel illumination is switched on for a few seconds. 2 While the contol panel illumination is on, touch the stand-by touch key.
Bringing up the OSD menu USING THE TOUCH KEYS: 1 While the OSD is not on the screen, touch any touch key. As a result, the control panel illumination is switched on for a few seconds. 2 While the contol panel illumination is on, touch the Enter key. touch USING THE CONTROL WHEEL: While the OSD is not on the screen, rotate the control wheel. Navigating through the OSD menus USING THE TOUCH KEYS: 1 Use the Up and Down keys to move through the menus.
Making selections in the OSD menus USING THE TOUCH KEYS: 1 Navigate through the menus and highlight the parameter you wish to select. 2 Touch the Enter several settings. key to make a selection or toggle between USING THE CONTROL WHEEL: 1 Navigate through the menus and highlight the parameter you wish to select. 2 Click the control wheel to make a selection or to toggle between several settings.
Advanced operation Info messages The following messages may appear automatically on the screen: INPUT SELECTION The Input selection menu appears in case 2 video signals are connected and the resolution of one or both video signals is too high to display them both. In that case the input selection menu allows you to select one of both video signals. NO SIGNAL SELECTED This message appears in case the display finds no proper video signal at its inputs.
LCM TEMPERATURE TOO HIGH This is a serious error message. You should power off the display and call for service. The warning means the LCD panel temperature is too high. As a result the display switches to a safe operating mode (with decreased backlight value). The message will not disappear until the display is powered off. LCM TEMPERATURE SENSOR OFF LINE This is a serious error message. You should power off the display and call for service.
On-screen display (OSD) Luminance and color menu Measured luminance Indicates the actual luminance measured by the internal sensor. This is a read-only value. It is expressed in cd/m2. Luminance target Allows to manually adjust the luminance target. See note below. Color target Allows to select from a list of factorydefined and user-defined color targets. Viewing mode Allows to select the viewing mode: Diagnostic or Text.
COLOR DEFINITION SUBMENU A color target is defined by its luminance target and color temperature. The color definition submenu allows to edit these values. Color name Indicates the color target you are editing. You can select another color target to edit by using the Up and Down touch keys or by rotating the control wheel. Luminance target Allows to select the luminance target that corresponds to the color target.
Color temperature Allows to define the color temperature that corresponds to the color target in Kelvin units. This function is available only when the color target is defined in Kelvin units. This function is available only when the User color target is selected. Restore factory x, y values Allows to reset the (x,y) co-ordinates of the color temperature to the factory values. This function is not available when the Native White color target is selected.
ALC & DICOM OPTIONS SUBMENU Measured ambient light Indicates the ambient light actually measured by the ambient light sensor on the front of the display. This is a read-only value. Averaged ambient light Shows the average of the measured ambient light since the display was switched on.
DICOM offset This function is available only when the DICOM DF is selected.When Continuous DICOM ALC is switched off, the DICOM DF is recalculated at the moment the DICOM Offset is changed, taking the new DICOM Offset into account. • When set to “Dark Room”, the ambient light is not taken into account. • When set to “Preset”, a preset ambient light value determined by the selected reading room is taken into account.
Calibration info Jumps to the calculation information submenu, which displays information about the values taken into account to recalculate the DICOM DF. READING ROOM DEFINITION SUBMENU Measured ambient light Indicates the ambient light actually measured by the ambient light sensor on the front of the display. This is a read-only value. Averaged ambient light Shows the average of the measured ambient light since the display was switched on. This is a read-only value.
Measured ALC value The value shown here is taken into account in the calculation of the DICOM DF if Continuous DICOM ALC is switched off and DICOM Offset is set to “Measured ALC”. When you select this line and confirm the selection, the actual averaged ambient light value is stored here, overwriting the former value.
Settings menu DPMS Allows to switch the display power management system on/off. See note below. Power LED Allows to switch the power LED’s on state on/off. The LED's orange DPMS state is not influenced by this setting. So, when the display goes into power-saving mode, the LED will turn orange, even if it was switched off by this setting User controls Allows to disable the user controls on the front. When switched off, the user cannot display the OSD until the user controls keycode is entered.
OSD Orientation Select the desired orientation of the onscreen display. The default position is Landscape, but if you put the display in portrait orientation (possible but not supported), you should select Portrait as OSD orientation as well. If not, the OSD will not be easily readable. Input Switch Mode Select “Auto” if you wish the display to select the video inputs automatically. If only one video input is connected, the image will be shown in the center of the screen.
Exclude I Guard zone When switched on, the video resolution of the preferred input is set to a value with a reduced number of lines. The image will be displayed below the I-Guard patch. Scaling When switched on, the display will enlarge (scale up) low resolution video signals if possible. The DPMS system will power down the display when the connected computer is left idle for a certain time. Barco recommends to switch DPMS on to prevent image burnin (image retention) on the LCD panel..
Changing the viewing mode ABOUT VIEWING MODES The display contains two viewing modes. Diagnostic viewing mode provides the full calibrated luminance. This mode is intended for using the display in diagnostic applications. In Text mode, the luminance is approximately half of the luminance in Diagnostic mode. This is intended for using the display with office applications such as word processing.
TO ENABLE THE USER CONTROLS AGAIN USING THE TOUCH KEYS: 1 To enter the user controls keycode, the OSD must not be visible. 2 Touch any of the soft touch keys to switch on the front illumination. 3 While the illumination is on, touch the following keys in successive order: Enter , Down , Up , Down , Enter . As a result, the User Controls setting in the Settings menu is switched on again. TO ENABLE THE USER CONTROLS AGAIN USING THE CONTROL WHEEL: 1 The OSD must not be visible.
Switching Power LED on/off TO SWITCH THE POWER LED ON/OFF: 1 Open the OSD main menu. 2 Open the Settings menu. 3 Select Power LED. 4 Select On or Off. 5 Return to the Settings menu. When the display is switched in stand-by, the power LED will turn orange, even if the power LED setting is switched off. When the power LED setting is switched off, the LED will still turn on (green) when the display is on but receives no video signal. Switching DPMS on/off TO SWITCH DPMS ON/OFF: 1 Open the main menu.
Changing Display Functions Concepts • The Display Function menu lets you select a display function (DF). • When you select the DICOM DF you can define the DICOM DF to be recalculated taking the ambient light into account. This can be a continuous recalculation (“Continuous DICOM ALC” on) or single recalculation (“Continuous DICOM ALC” off).
Display function selection TO SELECT A DISPLAY FUNCTION (DF): 1 Open the main menu. 2 Open the Display Function menu. 3 Select Display Function. 4 Select the desired DF. 5 Return to the Display Function menu. You can select the following DFs: DICOM Select a DICOM display function for most medical viewing applications. The DICOM function results in more visible grayscales in the images. Dynamic Gamma 2.2 Dynamic Gamma 1.
ALC & DICOM Options Continuous DICOM ALC INTRODUCTION When you select the DICOM DF, the display offers the possibility to take the ambient light into account for calculating the DICOM display function. This function is called Continuous DICOM ALC (ALC is short for Ambient Light Compensation). When Continuous DICOM ALC is switched on, the display will continuously adapt the DICOM DF based on the average measured ambient light.
TO SELECT A DICOM OFFSET: 1 Select the DICOM display function. See To select a display function (DF):, on page 43. 2 Switch Continuous DICOM ALC off. See To switch continuous DICOM ALC on/off:, on page 44. 3 In the ALC & DICOM Options menu, select DICOM Offset. 4 Select an offset. 5 Return to the ALC & DICOM Options menu. You can select the following offsets: Dark room The DICOM DF will be recalculated taking an ambient light value of 0 lux into account.
TO SELECT A READING ROOM SETTING: 1 Select the DICOM display function. See To select a display function (DF):, on page 43. 2 Switch Continuous DICOM ALC off. See To switch continuous DICOM ALC on/off:, on page 44. 3 In the ALC & DICOM Options menu, select Reading Room. 4 Select the reading room that corresponds to the room type the display is installed in. 5 Return to the menu.
Reading room definition This function is available only when the DICOM display function is selected and Continuous DICOM ALC is off. TO MODIFY A READING ROOM DEFINITION: 1 Select the DICOM display function. See To select a display function (DF):, on page 43. 2 Switch Continuous DICOM ALC off. See To switch continuous DICOM ALC on/off:, on page 44. 3 In the ALC & DICOM Options menu, select Reading Room Def. 4 Select the reading room definition you wish to modify. Thereto, first select Reading Room.
light value. Use Enter store the value. or click the control wheel again to • However, if you wish to adapt the ambient light conditions to the definition of the selected reading room, dim the light in the room so that the measured ambient light becomes lower that the maximum ambient light. • Then use Enter or click the control wheel again to execute the Measure ALC Value function once more. As a result the actually measured ambient light value will be copied as Measured ALC Value.
Cleaning your display Front glass Clean the front glass using a sponge, cleaning cloth or soft tissue, lightly Before cleaning the front glass, unplug the power cable from the mains to prevent the keys from being activated inadvertently by sweeping over them. moistened with one of the following tested products: • Flux • Pril • Windex Glass Plus • Ajax glass cleaner • Bohle glass cleaner • Sidolin glass cleaner • Mr.
Do not use following products: • Alcohol/solvents at higher concentration > 5% • Strong alkalis lye, strong solvents • Acid • Detergents with fluoride • Detergents with ammonia • Detergents with abrasives • Steel wool • Sponge with abrasives • Steel blades • Cloth with steel thread Cabinet 1 Clean the cabinet using a soft cotton cloth, lightly moistened with a recognized cleaning product for medical equipment.
Important information Safety information GENERAL RECOMMENDATIONS Read the safety and operating instructions before operating the display. Retain safety and operating instructions for future reference. Adhere to all warnings on the display and in the operating instructions manual. Follow all instructions for operation and use.
POWER CONNECTION - DISPLAY WITH EXTERNAL 24 VDC POWER SUPPLY • Power requirements: The display must be powered using the delivered medical approved 24 VDC SELV power supply. • The medical approved DC power supply must be powered by the AC mains voltage (protective earth terminal). TRANSIENT OVER-VOLTAGE If the equipment is not used for a long time, disconnect it from the AC inlet to avoid damage by transient over-voltage.
heed the necessary space between the set and the sides of the cupboard. INSTALLATION Place the display on a flat, solid and stable surface that can support the weight of at least 3 displays. If you use an unstable cart or stand, the display may fall, causing serious injury to a child or adult, and serious damage to the equipment.
Environmental information DISPOSAL INFORMATION (WASTE ELECTRICAL AND ELECTRONIC EQUIPMENT) This symbol on the product indicates that, under European Directive 2002/96/EC governing waste from electrical and electronic equipment, this product must not be disposed of with other municipal waste. Please dispose of your waste equipment by handing it over to a designated collection point for the recycling of waste electrical and electronic equipment.
中国大陆 ROHS (CHINESE MAINLAND ROHS) 根据中国大陆 《电子信息产品污染控制管理办法》(也称为中国大 陆 RoHS),以下部分列出了 Barco 产品中可能包含的有毒和 / 或有 害物质的名称和含量。中国大陆 RoHS 指令包含在中国信息产业部 MCV 标准:“ 电子信息产品中有毒物质的限量要求 ” 中。 According to the "China Administration on Control of Pollution Caused by Electronic Information Products" (Also called RoHS of Chinese Mainland), the table below lists the names and contents of toxic and/or hazardous substances that Barco's product may contain.
电源供应器 Power supply unit 文件说明书 Paper manuals 光盘说明书 CD manual X O O O O O O O O O O O O O O O O O O: 表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T 11363-2006 标准规定的限 量要求以下 . O: Indicates that this toxic or hazardous substance contained in all of the homogeneous materials for this part is below the limit requirement in SJ/T11363-2006. X: 表示该有毒有害物质至少在该部件的某一均质材料中的含量超出 SJ/T 11363-2006 标准规 定的限量要求 .
Regulatory compliance information INDICATIONS FOR USE: CORONIS FUSION 4MP The Coronis Fusion 4MP (MDCC-4130) display is a display device capable of displaying two 2MP display images electronically fused together on the one panel. It is intended to be used in displaying and viewing digital images for review and analysis by trained medical practitioners. It provides a screen resolution of 2560x 1600 pixels at a pixel pitch of 0.2505mm. This provides the equivalent resolution of 2 x 2MP displays.
are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
EMC notice No specific requirement on the use of external cables or other accessories except power supply. With the installation of the device, use only the delivered power supply or a spare part provided by the legal manufacturer. Using another can result in a decrease of the immunity level of the device. ELECTROMAGNETIC EMISSIONS The CORONIS FUSION 4MP/6MP display is intended for use in the electromagnetic environment specified below.
accept any interference received, including interference that may cause undesired operation. Interference can be determined by turning the equipment off and on. If this equipment does cause harmful interference to, or suffer from harmful interference of, surrounding equipment, the user is encouraged to try to correct the interference by one or more of the following measures: • Reorient or relocate the receiving antenna or equipment. • Increase the separation between the equipment and receiver.
ELECTROMAGNETIC IMMUNITY The CORONIS FUSION 4MP/6MP display is intended for use in the electromagnetic environment specified below. The customer or the user of the CORONIS FUSION 4MP/6MP display should assure that it is used in such an environment. Immunity test IEC 60601 Compliance level Electromagnetic environment – guidance ± 6kV contact ± 6kV contact ± 8kV air ± 8kV air Floors should be wood, concrete or ceramic tile.
Immunity IEC 60601 test test level Level Electromagnetic environment – Power frequency (50/60 Hz) magnetic field 3 A/m Not applic able Power frequency magnetic fields should be at levels characteristic of a typical location in a typical commercial or hospital environment.
6MP display is used exceeds the applicable RF compliance level above, the CORONIS FUSION 4MP/6MP display should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the CORONIS FUSION 4MP/6MP display. b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than 3 V/m. At 80 MHz and 800 MHz, the higher frequency range applies. These guidelines may not apply in all situations.
RECOMMENDED SEPARATION DISTANCE The CORONIS FUSION 4MP/6MP display is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled.
Explanation of symbols On the display or power supply, you may find the following symbols (nonrestrictive list): 0120 Indicates compliance to the essential requirements of the Directive 93/42/EEC Indicates compliance with Part 15 of the FCC rules (Class A or Class B) Indicates the display is approved according to the UL regulations or or Indicates the display is approved according to the c-UL regulations Indicates the display is approved according to the DEMKO regulations S&E Indicates the display is
Consult the operating instructions Indicates this apparatus must not be thrown in the trash but must be recycled, according to the European WEEE (Waste Electrical and Electronic Equipment) directive Legal disclaimer DISCLAIMER NOTICE Although every attempt has been made to achieve technical accuracy in this document, we assume no responsibility for errors that may be found. Our goal is to provide you with the most accurate and usable documentation possible; if you discover errors, please let us know.
photocopying, taping or information storage and retrieval systems without written permission of Barco. © 2013 Barco N.V. All rights reserved. PATENT INFORMATION This product is covered under the following intellectual property rights: US Patent RE43,707 US Patent 7,038,186 US Patent 7,166,829 US Patent 6,950,098 European Patent 1 274 066.
Technical specifications CORONIS FUSION 4MP Product acronym MDCC-4130 Screen technology TFT AM Color LCD Dual Domain IPS-Pro Active screen size 758.36 mm (29.9") (diagonal) Active screen size (H x V) 641.208 x 404.808 mm (25.25 x 15.94") Aspect ratio (H:V) 16:10 Resolution native 4MP (2560 x 1600) configurable to 2 x 2MP+ (1280 x 1600) configurable to 2 x 2MP (1200 x 1600) Pixel pitch 0.
Response time (Tr + Tf) 20 ms Scanning frequency (H; V) 30-150 kHz; 15-80 Hz Housing color Black/Silver Video input signals DVI-D Dual Link (2x) Video inout terminals NA USB ports 1 upstream (endpoint), 3 downstream USB standard 2.
Swivel -45° / +45° Pivot NA Mounting standard VESA (100 mm) Screen protection Protective, non-reflective glass cover Recommended modalities CT, MR, US, DR, CR, NM, Film Certifications CE0120 (MDD 93/42/EEC; A1:2007/47/EC class IIb product), CE - 2004/108/EC, CE - 93/42/EEC; A1:2007/47/EC class II b, IEC 60950-1:2005 + A1:2009 (2ND EDITION), IEC 60601-1 2ND ED:1988 + A1:1991 + A2:1995, UL 60601-1 1ST EDITION, CAN/ CSA-C22.2 NO. 601.
CORONIS FUSION 6MP Product acronym MDCC-6130 DL Screen technology TFT AM Color LCD Dual Domain IPS-Pro Active screen size 772 mm (30.4") (diagonal) Active screen size (H x V) 654 x 409 mm (25.8 x 16.1") Aspect ratio (H:V) 16:10 Resolution native 6MP (3280 x 2048) configurable to 2 x 3MP+ (1640 X 2048) configurable to 2 x 3MP (1536 X 2048) Pixel pitch 0.
Scanning frequency (H; V) 30-150 kHz; 15-80 Hz Housing color Black/Silver Video input signals DVI-D Dual Link (2x) Video inout terminals NA USB ports 1 upstream (endpoint), 3 downstream USB standard 2.
Swivel -45° / +45° Pivot NA Mounting standard VESA (100 mm) Screen protection Protective, non-reflective glass cover Recommended modalities CT, MR, US, DR, CR, NM, Film Certifications CE0120 (MDD 93/42/EEC; A1:2007/47/EC class IIb product), CE - 2004/108/EC, CE - 93/42/EEC; A1:2007/47/EC class II b, IEC 60950-1:2005 + A1:2009 (2ND EDITION), IEC 60601-1 2ND ED:1988 + A1:1991 + A2:1995, UL 60601-1 1ST EDITION, CAN/ CSA-C22.2 NO. 601.
Coronis Fusion 4MP/6MP
Coronis Fusion 4MP/6MP 75
K5902015-08 February 2013 0120 Barco n.v. President Kennedypark 35 8500 Kortrijk Belgium www.barco.