Owner's Manual

Table Of Contents
R5900087 /06 ClickShare CSE-200+92
Image 636 Service, SNMP
4. Check the check box in front of Enable.
The configuration fields become available.
How to configure
1. When using the default Engine ID, make sure the check box before Use default Engine ID is checked.
The default engine ID is a combination of the Barco Enterprise Number with the MAC-address (eth0).
2. Fill out the SNMP Manager address.
That is the host address which will receive the TRAP events/messages.
Possible traps can be:
Alarm CPU temperature trap which indicates that CPU temperature exceeds the threshold.
Alarm Case Fan Speed trap which indicates the case fan is spinning too slow.
Alarm Process Not Running trap which indicates one of the monitored processes is not running.
3. Enter the Username.
4. Enter a new password and confirm that password.
6.25 Services, Remote Button Pairing
About remote Button pairing
When using ClickShare Button Manager, a stand alone software application on your computer, you can
manage your Buttons on most of the types of ClickShare Base Units. Your computer can pair up to four
Buttons at once with a known Base Unit. It is not necessary anymore to physically connect the Button with the
Base Unit to pair it. This functionality makes it easy to use any Button with any Base Unit. Before you can use
the ClickShare Button Manager a password must be configured on each Base Unit.
How to setup
1. Log in to the Configurator.
2. Click Wi-Fi & Network Services.
3. Scroll to Remote Button Pairing.
Image 637 Service, Remote Button pairing
CSE-200+ Configurator