user manual
DX-700 • User’s Guide  • Rev 02 133
4. Operation
Using the Display Management Menu
b.  Select the desired test pattern and its associated parameters. Receiver 
test pattern options are identical to transmitter test pattern options. 
9.  To view current Fiberlink properties:
a.  Press {Properties} to display the Fiberlink Properties Menu:
Figure 4-70.  Fiberlink Properties Menu (sample)
b.  Press {Previous} to return to the Fiberlink Menu.
c.  Press {Previous} to return to the Fiberlink Processing Menu.
This completes the 
Fiberlink management procedure.
cçêÅáåÖ=íÜÉ=aáëéä~ó
An LED wall’s power can be forced on or off, as required.
 Use the following steps to force the display:
1.  From the Home Menu, press {Display Management}.
2.  Immediately above the graphic, press the button for the bank that contains the 
output whose display you wish to force on or off.
3.  On the selected bank, press the output that you wish to manage. The Display 
Management Menu 
appears. 
~ Press {Force Display On} to turn the selected LED wall’s power on.
~ Press {Force Display Off} to turn the selected LED wall’s power off. 
When the confirmation message appears:
• Press 
{Yes} to turn wall power off.
• Press 
{No} to leave the wall’s power on.
Both options return you to the 
Display Management Menu.
This completes the 
Force Display procedure.
Note
If both the Transmitter and Receiver test patterns are 
enabled, only the test patterns from the Receiver will be 
displayed on the LED wall.