DX-700 Management Menu Operations
6.  Press {Previous} to return to the Input Connection Menu. Here, you can set up 
EDID for the module’s other connector, or press 
{Previous} to return to the Input 
Selection Menu.
7.  As required, repeat the procedure from step 3 to set up other input modules.
8.  When EDID setup is complete, press {Previous} to return to the DX-700 
Management Menu
.
This completes the 
EDID Setup procedure.
råÇÉêëí~åÇáåÖ=dÉåäçÅâ=léíáçåë
Genlock is the practice of synchronizing the video output of one device to a reference 
source signal, thus ensuring flicker-free video transmission across multiple input and output 
devices. The DX-700 provides a number of genlock options:
• You can lock a single output (or group) to the same signal as the bank’s genlock 
source, or to a different source, or set it to freerun at a specified freerun rate. The 
default setting locks an output to the bank’s sync source.
• You can synchronize an entire bank’s signal to the master genlock source for the 
system, or a different source, or set it to freerun at a specified freerun rate.
• You can lock the entire DX-700 to a single internal or external signal, or set the 
DX-700 to freerun at a specified freerun rate. 
• You can set individual outputs or output groups on different banks to the same 
sync source.
This section explains these options in the following topics:
• Setting Genlock Using the Bank Sync Menu
• Setting the Master Sync Source
pÉííáåÖ=dÉåäçÅâ=rëáåÖ=íÜÉ=_~åâ=póåÅ=jÉåì
The =Bank Sync Menu enables you to select the source to which the LED and monitor 
outputs in a bank are genlocked. Three different methods are available:
• When Freerun is selected, the bank is locked to its own internal timing generator 
— and 
not to an external source. In this mode, the system is not synchronous 
with other equipment in your video system, but you can set the refresh rate. 
• When Input is selected, the bank is locked to a specific input on a selected input 
module. In this mode, the system 
is synchronous with external equipment. 
• When Master Sync is selected, the bank is locked to the master sync source. 
You use the 
Master Sync Menu to set the master sync source. 
Important
Video processing delay through the DX-700 is affected by the 
selected genlock mode, the type of input, and the selected 
delay mode. In Chapter 1, refer to the “
DX-700 Video 