56 DX-700 • User’s Guide • Rev 02
2. Hardware Orientation
Module Installation and Configuration
• In multi-bank configurations, all banks must be directly adjacent to one another, 
with no blank panels in between.
Figure 2-14.  Adjacent banks 
Blank
Input
Input
Input
Output
System
Power
Input
Output
Correct Justification
Incorrect Justification
Bank 1
Bank 2
Input
Input
Input
Output
System
Power
Output
Input
Blank
Bank 1 Bank 2
Important
With the exception of “spare” modules, if the DX-700 
determines that any modules are incorrectly installed (or 
missing), a 
Startup Diagnostic Menu appears which 
prompts you to power down the DX-700 and re-configure your 
modules properly.  
If the above prompt occurs, and provided that a System 
Module is properly installed, on the 
Startup Diagnostic 
Menu
 you will be able to press the {DX-700 Management} 
button, and access a subset of management functions. In 
Chapter 4, refer to the “
Power-Up Initialization” section on 
page 77 for details.
Important
The DX-700 will not recognize modules that are installed to 
the left of a blank panel. They will be treated as spares. 
Refer to the “
Storing Spare Modules” section on page 59 for 
additional details.
Important
Multi-bank configurations are currently not implemented.
Important
For proper chassis cooling, slots that do not contain 
input or output modules must always have blank panels 