aK==oÉãçíÉ=`çåíêçä
Using Remote Control
bñíÉêå~ä=pÉêá~ä=oçìíÉê=`çåÑáÖìê~íáçå
The figure below illustrates the connections required for the following configuration:
Two (or more) ScreenPRO-II units are used as unique destinations.
One external serial controlled router (RS-232) is used for analog source
connections to each ScreenPRO-II.
One external serial controlled router (RS-232) is used for SDI source connections
to each ScreenPRO-II.
Figure D-2. ScreenPRO-II Units using External Serial Controlled Routers
Use the following steps to connect ScreenPRO-II units as destinations, using external
serial controlled routers:
1. Using a standard Ethernet cable, connect the Ethernet Port on the rear of the
ScreenPRO-II chassis to your system’s Ethernet
Hub (or Switch). In Chapter 2,
refer to the “
ScreenPRO-II Rear Panel” section on page 12 for the location of the
Ethernet port.
2. Repeat step 1 as required for each ScreenPRO-II chassis that you wish to use as
a destination.
Encore Controller (SC or LC)
Ethernet
ScreenPRO-II
MatrixPRO SDI Router
MatrixPRO Analog Router
RS-232
RS-232
RS-232
Lantronix
UDS200
Ethernet
Outputs
Inputs
Hub / Switch
Note
A completely “local” network is strongly recommended,
without IP connections to the outside world.