Specifications

Manual 2100-317
Page 33
FIGURE 17
MIS-1210
ACCESSORIES
ADD-ON DPM26A PUMP MODULE KIT
NOTE: This section applies only if a DPM26A Pump
Module is added. Refer to DPM26A instructions
for complete installation details.
GENERAL
This high efficiency water source heat pump series was
designed with a refrigerant to water heat exchanger
commonly know as a desuperheater coil factory-installed
for ease in installing optional DPMA pump module kit.
The addition of this optional kit allows for heat recovery
for hot water heating when connected to a home water
heater. The amount of annual hot water supplied and thus
additional energy cost savings will depend on the amount
of hot water usage and the number of hours the heat
pump operates. This pump kit is suitable for potable
water.
INSTALLATION
1. Follow all local, state, and national codes applicable
to the installation of the pump module kit.
2. Follow the installation instructions received with the
DPM26A pump module kit.
3. Connect the water lines between the unit, pump
module kit, and the water heater.
SERVICE
SHUTOFF
VALVE
WATER FROM
WATER HEATER
SERVICE
SHUTOFF VALVES
WATER TO UNIT
WATER TO
WATER
HEATER
WATER FROM
PUMP KIT
DPM26A
GSVS MODEL