User's Manual Part 2

Host Computer Commands
RVP8 Users Manual
May 2003
6–30
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
| | | | | | | | | | | | | | | | |
| | IFD Sat.Power | MinRev | Inter.F | Output 52
|_______________|_______________|_______________|_______________|
Inter.F Specifies which interference filter is running. Zero means “none”; see Section
5.1.4 for a description of the interference filter algorithms.
MinRev Minor revision level of the RVP8 code that is currently running.
IFD Sat.Power (P
MAX
)
Input power required to saturate the IF-Input A/D converter for the RVP8/IFD re-
ceiver that is currently attached.
0: +4.5dBm 1: +6.0dBm
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
| | | | | | | | | | | | | | | | |
| Interference Filter Parameter “C1” in Hundredths of deciBels | Output 53
|_______________________________________________________________|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
| | | | | | | | | | | | | | | | |
| Interference Filter Parameter “C2” in Hundredths of deciBels | Output 54
|_______________________________________________________________|
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
| | | | | | | | | | | | | | | | |
| Immediate Status Word #3 (Current State of Affairs) | Output 55
|_______________________________________________________________|
Bit 0 Burst pulse timing adjustments can be made
Bit 1 Burst pulse frequency adjustments can be made
Bit 2 Burst pulse hunting is enabled
Bit 3 Burst pulse hunt is running right now
Bit 4 Last burst pulse hunt was unsuccessful
Bit 5 Dual PRT Type 2 is supported
Bit 6 Could not generate the requested phase sequence
Bit 7 Problem with digital transmitter clock
Bits 8-11 User-defined Major Modes 1-4 are supported
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
| | | | | | | | | | | | | | | | |
| Signed trigger slew in hundredths of microseconds | Output 56
|_______________________________________________________________|
This is the same format that is used by the SETSLEW command to set the current trigger slew
(See Section 6.24)
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
| | | | | | | | | | | | | | | | |
| Polarization Algorithm Choices | Output 57
|_______________________________________________________________|
Bit 0 Use H transmissions for (T,Z,V,W)
Bit 1 Use V transmissions for (T,Z,V,W)
Bit 2 Use Co–Pol reception for (T,Z,V,W)