Programming Manual
i480e&i480e-MD2 Programming Manual
35 / 139
5 Generic Indication Definition
5.1INIT
The INIT indication is used to inform the host unit if the Bluetooth initialization
is successfully completed.
Indication
AT-B INIT [status]
Parameters
status
0: succeeded;
1: failed.
Note
N/A
5.2ROLE
The ROLE indication is used to inform the host of current role in the specific
connection.
Indication
AT-B ROLE [role]
Parameters
role
0: master;
1: slave;
2: role doesn’t care.
Note
N/A
5.3SSPPIN
The SSPPIN indication is used to inform the SSP PIN code.
Indication
AT-B SSPPIN [pin]
Parameters
pin
SSP PIN code
Note
N/A
Barrot Confidential