Programming Manual
i480e&i480e-MD2 Programming Manual
51 / 139
7.10
HFNUMC
The HFNUMC indication is used to inform the host that the query of subscriber
number is completed.
Indication
AT-B HFNUMC [status]
Parameters
status
Values in the chapter 6.1.1.
Note
N/A
7.11
HFSGNL
The HFSGNL indication is used to inform the host unit of the signal strength of
the AG side.
Indication
AT-B HFSGNL [signal]
Parameters
signal
Signal strength indicator, where ranges from 0 to 5.
Note
N/A
7.12
HFROAM
The HFROAM indication is used to inform the host unit of the roaming status of
the AG side.
Indication
AT-B HFROAM [roam]
Parameters
roam
Roaming status indicator, where:
0: roaming is not active;
1: roaming is active.
Note
N/A
7.13
HFBATC
The HFBATC indication is used to inform the host unit of the battery charger
status of the AG side.