Owner's Manual

2
Specifications
WL2x Level Monitor
Measurement Method .............. Micropower Impulse Radar (MIR)
Measured Value ...................... Level
Accuracy ................................ ±0.25" or 0.5% of probe length
(whichever is greater)
(1)
Output ................................... Transmits ID, level data, and diagnostics
Radio Communications ........... Transmits and receives up to 500' (150 m),
line-of-sight, in 902-928 MHz band (North
America) or 869.7-870 MHz band (Europe)
Operating Temperature ........... -40°F/°C to +140°F (+60°C)
Power Requirements ............... Battery Pack [4-AA Alkaline]
Construction ........................... Weatherproof, non-corrosive, NEMA-4/IP65
enclosure
Pressure Rating....................... 15 PSI (1 bar) maximum
Construction Materials ............. Teflon/Brass or Teflon/SST, Plastic (20% glass
filled Polybutylene Terephthalate polyester
(PBT), and Epoxy
Approvals............................... Intrinsically Safe;
CSA (Class I, Div. 1, Groups C & D);
EEx ia IIB T4; UL Pending
Mounting ............................... 2 inch and 1-1/2 inch NPT (standard)
Shipping Weight (approx.) ....... Monitor and Probe — 2.4 lbs (1.1 kg)
Notes: (1) Active probe length does not include top 3" (75 mm) or bottom 3" (75 mm) of
specified probe length. See dimension drawing below.
(2) Probe length should be selected so no portion will contact the tank bottom.
Replacement Parts List
Part Description Part Number
Battery Pack ........................... 0130-1043T (Standard, non-hazardous)
0130-1044T (Cenelec, intrinsically safe)
Dimensions