AV-03BD Exported on 08/12/2019
Table of Contents Device description................................................................................................ 5 Appearance.....................................................................................................................................5 Technical parameters.......................................................................................... 6 GENERAL CHARACTERISTICS...............................................................................................
Installation and connection.............................................................................. 21 Completness check of the product ..................................................................................... 21 Electrical connection ................................................................................................................. 21 Mechanical mounting ...............................................................................................................
• • • • • Device description(see page 5) Technical parameters(see page 6) Configuration through WEB interface(see page 8) Installation and connection(see page 21) Usage of the device(see page 25) – 4
Device description BAS-IP AV-03BD is a stylish panel that will surely fit perfectly into the interior of any office center. The panel is made of high quality plastic and can be used in almost any room.
Technical parameters GENERAL CHARACTERISTICS Panel Type: Individual Display: No Camera: 1/4" Viewing angle: horizontal 100°, vertical 52° Camera resolution: 1 MP Output video: 720p (1280x720), H.264 Main profile Night lights: 6 LEDs Minimum illumination: 0.01 LuX Protection class: IP40 Temperature condition: -10 - + 40° С Power consumption: 6.5 W, standby 2.
Optional: SIP P2P, Built-in Relay Technical parameters – 7
Configuration through WEB interface • • • • • • • • Login(see page 8) Main(see page 8) Network(see page 10) Device(see page 11) Access management(see page 13) Forward(see page 17) Advanced(see page 19) System(see page 19) Login To configure the call panel remotely via the WEB interface, you need to connect to it with an Internet browser on your PC. The panel must be connected in the same network segment as the PC from which it is planned to perform the configuration.
Device info Framework: A version of the framework. Launcher: A version of the launcher. Network info DHCP: Current DHCP status. IP адрес: Current IP address of the device. Subnet mask: Used subnet mask. Gateway: Gateway address. DNS server: DNS server address. MAC address: Physical address of the device.
Network DHCP: Enable/disable the automatic retrieval of network settings. IP: Panel IP address. By default, the call panel can have a static IP address 192.168.1.90 or 192.168.1.91. Mask: Subnet mask. Gateway: The main gateway. DNS: DNS server address. Custom NTP Current device date/time: Shows the current device's date and time. URL: Field to enter custom NTP server address. Timezone: Choose used timezone.
Device Apartment settings Mode: Panel's operation mode. Building: Building number. Unit: Unit number. Flor: Floor number. Apartment: Apartment number. Device number: Device numeration number. Numeration of the panels If you have several call panels that have one logical address, then in the "No." field specify the value 2, 3, 4, 5, etc., up to 9.
Enable/Disable: Enable/disable SIP registration. Proxy: A proxy SIP server that can be represented by both an IP address and a domain name. Data format: Before the proxy address, you must specify "sip:". Server: SIP server address. Data format: Сan be represented by both an IP address and a domain name. STUN IP: STUN server address. Example: stun.l.google.com. STUN port: The port of the STUN server. Example: For google STUN server 19302 port is used. Password: Password of SIP number.
The maximum time for calling: The time interval after which the panel automatically ends an outgoing call if there is no answer. Maximum talk time: The time interval after which the panel automatically ends the outgoing conversation. Device settings Video quality: Select your preferred video resolution. RTP data profile: Select your preferred RTP data profile. Volume Level: Adjusts the speaker volume of the panel.
Common settings Master card: Master card number. Use master code: Enable/disable using master code to open the lock. Master code: The code entered on the keypad for opening the lock. When using the control module with two locks SH-42, when entering the master code on the panel, both locks will open. Registering access cards via web interface Enter 0 in the “Master card” field and click the “Apply” button.
Keep the lock open, if there is no SIP registration: Function to automatically open the lock if SIP registration on the panel is lost. No Sip registration time: Time period after which the lock begins to open if SIP registration on the panel is lost. Open lock Lock #1, Lock #2 Open lock: The function of opening the selected lock from the panel WEB interface.
New identifier After clicking on the "New identifier" button, the following interface will appear: Identifier number: Number of identifier in decimal format.
Unit number 00-99 Floor: Floor number 00-99 Room: Room number 01-99 Forward This section is used to substitute numbers by means of the panel when making calls to internal monitors when there is no monitor or it is turned off, or to any given SIP number. Forward settings Mode: Mode of the forwarding. All at once - the call is made to all numbers simultaneously. One by one - the call is made to the numbers in turn with a delay of 20 seconds.
After clicking on the "New Forward" button, the following interface will be displayed: Apartment number: Number dialed on the panel's keypad. Forward Number: The direction in which the call will be made when you enter the corresponding number on the keypad. It can be used both for calls within the LAN via P2P, and for SIP calls. Input format for internal calls sip:1@192.168.1.65, where 1 is the desired number to be displayed by the called party, 192.168.1.
Advanced RTSP feed: Function to view additional IP cameras during a call (up to 4 streams). This feature is available for v4 monitors and any other SIP devices with a keyboard. During a call, it is possible to switch between streams by pressing keys 1 through 5. The key "1" corresponds to the stream of the camera of the call panel, the keys from "2" to "5" - to additionally added streams (transmission is done by DTMF RFC2833). Url: Address of the RTSP stream displayed during the call.
Settings Choose file: Selecting the panel configuration file from the PC file system. Set default settings: Reset all panel settings to factory defaults. Backup all settings: Save and export configuration files. Device language Choosing the language of the device. Reboot Reboot: Soft reset of the panel.
Installation and connection This page describes the process of installing and connecting the call panel. • • • • Completness check of the product(see page 21) Electrical connection(see page 21) Mechanical mounting(see page 23) Connection of additional modules(see page 24) Completness check of the product Before installation of the outdoor panel, it is necessary to check that it is complete and all components are available.
2. Connection scheme of electromagnetic lock using external power supply for panel and the lock.
Mechanical mounting Before mounting the door panel, a hole or recess in the wall with dimensions of 20 × 50 × 60 mm (for flush mounting) must be provided. It is also necessary to provide for the supply of power cable, add. modules and local network.
Connection of additional modules The following modules can be connected to the outdoor panel: • Module to control two locks SH-42 Installation and connection – 24
Usage of the device • UKEY mobile access(see page 25) • Recieving the RTSP stream from the panel's camera(see page 29) UKEY mobile access Description Ukey Mobile Access from BAS-IP is a universal technology for gaining access to the premises or to the territory of an object with the possibility to use in one reader simultaneously: EM-Marin cards and MIFARE/encrypted cards MIFARE Plus/MIFARE Classic, cell phone (Bluetooth and NFC).
For users' ease of operation with BAS-IP outdoor panels equipped with multi-format readers, the company BAS-IP has released a new mobile Ukey application which, after receiving the mobile ID, is used to open the doors/gates/parking gate arms. For each outdoor panel equipped with a reader module with support for UKEY Mobile access, a different range of the mobile ID can be configured, in the range of 2 centimeters to 10 meters.
The user submits an application to purchase the required number of QR-codes to the administrator of his service company, wherein one QR-code = one mobile device. Afterwards, the user gets the QR-code in the printed form or in electronic form (by e-mail, Viber, Telegram, etc.). Then the user scans the code received or imports it from the file system and thus gets the mobile ID.
2. Install and launch the program on a PC with the Windows Family OS to write the identifiers "BAS-IP USB Reader Server"; 3. Connect the reader to PC; 4. Bring a master-card to the reader; 5. Bring a cell phone to the reader (make sure Bluetooth is on) and enter UKEY App, then press Obtain button or select Obtain BAS-IP TR-03 key. 6. The reader will transmit a mobile ID to your cell phone, thus "Your key is ready" will appear in the app.
Recieving the RTSP stream from the panel's camera To get the RTSP stream from the camera of the call panel to the video surveillance system, you need to put in the add line of the camera rtsp://admin:123456@192.168.1.16:8554/ch01, where admin is the login, 123456 is the password to access the WEB interface, 192.168.1.16 is the IP address of the panel, 8554 is the port of access to the camera, ch01 is the channel number.
FCC Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications.