Instructions / Assembly

Dual Float Switch
The dual float switch contains two large
floating rings enclosed within a protective
cage. Water will lift the bottom float by a
14, which will activate the pump. If for any
reason the lower float does not activate the
pump, the water will rise and activate the
second switch. As the pump evacuates the
water from the pit, the floats will drop. The
pump will run for an additional 10 seconds to
extend the cycle after the float returns to its
original position.
Note: When mounting the float switch, position
the bottom of the cage at the height you want
the pump to activate.
Installing the Dual Float Switch
The Basement Watchdog dual float switch is
easy to install by using the enclosed metal hose clamp.
1. Hold the float switch to the discharge pipe so the cage is below the
bracket.
2. Secure the float to the pipe with the enclosed hose clamp, but do not
completely tighten the clamp at this time.
3. Position the float switch to a level where the bottom of the float cage is
no lower than 3 above the bottom of the pump and no higher than 1
below the top of the pit. To avoid debris pouring into the float, it should
be positioned on the side of the discharge pipe opposite the drain tile.
Note: It is important to mount the float below the drain tile that empties
into the pit. Mounting it above the drain tile would allow water to fill the
drain tile before the pump is activated to pump out the water.
4. Once the float switch is in the desired position, tighten the clamp.
ALWAYS disconnect the pump and dual float controller from the power source
before servicing or making adjustments.
NEVER handle the controller, float switch, pump or motor with wet hands or when
standing on a wet or damp surface while the pump or controller is plugged into
the power source.
MAKE SURE THERE IS A PROPERLY GROUNDED RECEPTACLE AVAILABLE. This
controller is wired with a 3-prong grounded plug. To reduce the risk of electric
shock, be certain that it is only connected to a properly grounded, 3-prong
receptacle. If you have a 2- prong receptacle, have a licensed electrician replace it
with a 3-prong receptacle according to local codes and ordinances.
NEVER bypass grounding wires or remove the ground prong from the controller.
DO NOT use an extension cord. The electrical outlet should be within the length
of the pump’s power cord, and at least 4 feet above the floor level to minimize
potential hazards from flood conditions.
DO protect the electrical cord from sharp objects, hot surfaces, oil, and chemicals.
Avoid kinking the cord.
MAKE SURE the supply circuit has a fuse or circuit breaker rated to handle the
power requirements noted on the nameplate of the pump.
DO NOT expose the control unit to any type of moisture, water, rain or snow.
DO NOT operate the pump or control unit if it has been damaged in any way.
DO NOT use with pumps in pits handling raw sewage, salt water, or hazardous
liquids. This product is for use with ground water applications only.
DO NOT use in continuous duty applications such as fountains or ponds.
DO NOT disassemble the pump or control unit. When service is required, contact
Glentronics technical support at 800-991-0466, option 3. Return the product to
the manufacturer for any repairs at the following address:
Glentronics, Inc., 645 Heathrow Drive, Lincolnshire, IL 60069
The control unit must receive 115V AC +/- 5% and 60 Hz from the AC outlet.
The controller will not provide protection during a power outage. With the risk of
property damage from high water levels, the addition of a Basement Watchdog
battery backup sump pump system is highly recommended.
After the initial installation, be sure to check the operation by filling the sump
with water and observing the pump operation through one full cycle.
CAUTION
WARNING
NOTICES
Risk of electric shock. To reduce this risk, observe
the following precautions.
To reduce the risk of hazards that can cause injury or
property damage, observe the following precautions.
Basement Watchdog
Dual Float Switch
& Controller
Instruction Manual
& Safety Warnings
Installation Instructions
Prior to Installation
1. Visually inspect the product. Products may be damaged during shipping. If the
product has been damaged, contact your place of purchase or Glentronics, Inc.
before installation.
2. Thoroughly read the instructions provided to learn specific details regarding
installation and use. This manual should be retained for future reference.
SAVE THESE INSTRUCTIONS. This manual contains
important SAFETY WARNINGS and OPERATING
INSTRUCTIONS for the Basement Watchdog Dual Float
Controller. You will need to refer to it before attempting
any installation or maintenance.
ALWAYS keep these instructions with the unit so that
they will be easily accessible. Failure to read and follow
these warnings and instructions could result in property
damage, serious injury, or death.

Summary of content (2 pages)