Instructions / Assembly

Page 16
MAINTENANCE CHECK LIST
Maintenance should be performed 1-2 times per
year
1. Lift the float switch as described at left.
2. Remove all debris from the bottom of the pit
and pump strainer.
3. Remove all debris from the water.
4. Remove all debris from the float switch.
5. Fill the pit with water. Make sure the pump
turns on at the intended level.
6. While the pump is running, make sure the
pump is evacuating water at a good pace and
water is coming out of the 1/8” air bleed hole.
7. Remove the fluid sensor and yellow cap from
the battery and rinse any residue buildup from
the bottom of the battery cap. Replace the
cap and fluid sensor.
8. Check and clean battery terminals.
9. Check battery fluid levels once every four
months.
PARTS & SERVICE INFORMATION
You can receive technical support parts or
service information by calling Glentronics, Inc.
at 800-991-0466, option #3, or by visiting
the Basement Watchdog website at
www.basementwatchdog.com. Send your unit
to the following address if repairs are needed:
Glentronics, Inc.
645 Heathrow Drive
Lincolnshire, IL 60069-4205