Instructions / Assembly

Page 9
If your battery looks like the battery above,
follow these instructions:
1. Remove the cover of the battery box by
pushing in the tabs on the front and back of
the box and lifting up.
2. Place the battery box on the floor. Place the
dry (unfilled) battery into the battery box.
Remove the two battery caps by carefully
prying them up with a screwdriver as shown
on the right. Place the screwdriver in the
middle of the cap on the top of the battery.
DO NOT lift the cap by prying it up from the
groove on the back of the battery. It may
damage the vent.
3. Carefully push in the perforated tab at the top
of the acid pack. Lift up the large tab and pull
out the dispensing hose. Hold the hose
upright above the pack and squeeze the hose
forcing all the acid back into the pack.
4. Position the acid pack and battery as shown at
the right. Pinch the end of the hose together
and cut off the tip. Insert the end of the hose
into each cell. Control the flow by pinching
the hose with thumb and forefinger. Fill each
cell of the battery to a level just covering
the battery plates, and then go back and
top off each cell equally. It is important to
have all the cells filled equally
or the
battery will not operate properly. The acid
should reach a level about ¼” below the cap
ring as shown in the diagram below. DO NOT
OVERFILL THE BATTERY. (Diagram E)
A newly filled battery will sometimes require
additional acid after about 20 minutes. Re-
examine the fill level, and add additional acid if
necessary. The battery acid may bubble at this
time and give off a sulfur-like smell, but this is
normal. After the battery has been filled, press
the caps securely on the top of the battery.
When you fill the battery for the FIRST time,
it will be the ONLY time you add acid to the
battery. In the future, when the fluid level is
low, add distilled water to the cells. NEVER
add more acid.
Battery Maintenance
Measuring the battery fluid level is one of the
most important features of the system. It is
important to check the battery fluid levels at
least once every 4-6 months. Detailed
instructions on adding distilled water to the
battery can be found within the Understanding
the Warnings & Alarms section of this manual
(page 13,
3
Water). If you are not using a
Basement Watchdog standby battery, you cannot
use the battery fluid sensor. You will need to
attach the fluid sensor to the POSITIVE (+) post
of the battery or the alarm will sound
continuously. The system will NOT warn you if
the fluid level is low in this configuration. You
will need to check your battery every couple of
months to see if it needs water. If the battery
dries out, the system will not work. If you are
using a maintenance free battery or sealed AGM
battery you will also need to attach the fluid
sensor to the POSITIVE (+) post of the battery or
the or the alarm will sound continuously.
Control Unit Connections
Risk of electrical shock or battery explosion,
which can cause serious injury or death.
Unplug the main AC pump to avoid electrical
shock. Wear eye protection. Work in a well-
ventilated area. Do not smoke or allow a spark
or flame in the vicinity of the battery. Avoid
dropping metal tools on the battery. If battery
acid contacts eyes, flush with water for 15
minutes and get prompt medical attention.
Review the safety instructions on page 1.
When you position the battery with the control
unit on the top, be sure the charger cord will
reach the AC power outlet, and the pump cable
and the float switch will reach the bottom of the
sump. Position the unit in a well-ventilated
area. (Diagram F)
1. Positioning the dual float switch: The float
switch will activate the pump when the water
raises either float, and it will remain running
as long as the water is above the float. When
the water drops below the float switch, an
internal timer in the control unit will keep the
pump running an additional 25 seconds to
empty the sump pit. The switch should be
mounted about six
(6) inches above the
water level line in
the sump pit. Attach
the float switch very
securely to the
discharge pipe with
the plastic wire tie.
Be sure the switch is
positioned vertically
with the mounting
bracket at the top.
Do not tilt the switch. Do not position the float
switch on the side of the discharge pipe facing
the drain tile or any incoming rush of water!
2. Connecting the pump: Remove the security
tag from the pump and plug the pump wires
into the pump connector on the back of the
control unit. Keep the backup pump wire, the
AC pump wire, and the float wire separate
from each other. Do not let them cross on the
final installation.
3. Installing the battery fluid sensor:
BASEMENT WATCHDOG BATTERIES COME IN TWO
!
DANGER
BATTERY B
CAUTION
2nd LEVEL
1st LEVEL
PLATES
CELL WALL
1 1st LEVEL, COVER THE PLATES
THE BOTTOM OF THE CAP RINGS
BATTERY TERMINALS
BATTERY CAP RINGS
CROSS SECTION OF BATTERY
1. Fill to 1st level, cover
the plates
2. Then fill to 2nd level,
just below the bottom
of the cap rings
Diagram E
Do not throw an
old battery in the
trash. Take it to a
service station or
recycling center.