Use and Care Guide

2. Replace the pit cover making sure not to pinch or crimp the pump wire with the
cover. The pit cover either has a ‘hole punch’ that will allow the cord to be passed
through or one can be drilled in the cover.
Product Operation
Dual Float Switch
The dual float switch contains two large floating rings
enclosed within a protective cage. Water will lift the
bottom float by a
1
⁄4⬙, which will activate the pump. If for
any reason the lower float does not activate the pump, the
water will rise and activate the second switch. As the
pump evacuates the water from the pit the floats will drop.
The pump will run for an additional 10 seconds to extend
the cycle after the lower float drops. Note: When
mounting the float switch, position the bottom of the cage
at the height you want the pump to activate.
Dual Float Controller
The Dual Float Controller will activate the pump when
either float is lifted, and then shuts off automatically 10
seconds after the float drops. Plug the pump cord into the
piggyback switch on the control unit.
Operating the Pump in a Continuous
Duty Application
The Basement Watchdog pumps are rated for continuous duty and may be used in
applications requiring continuous pumping including fountains, ponds, etc. For use in
any continuous duty application the pump should be plugged directly into the wall
outlet without the use of the controller. The outlet must be a single phase properly
grounded 3-prong receptacle, 115V, 60HZ (preferably with ground fault circuit
interrupt). For continuous duty operation, the pump must be submerged at least 3/4 of
the depth of the pump at all times.
Maintenance Check List
Maintenance should be performed 1-2 times per year.
1. Remove all debris from the bottom of the pit.
2. Remove all debris floating in the water.
3. Remove all debris from the float switch cage.
4. Fill the pit with water. Make sure pump turns on at the intended level.
5. While the pump is running, make sure pump is evacuating water at a good pace.
Backup Installation
When the power goes out, the Basement Watchdog AC sump pumps will not operate.
For protection during a power outage, a Basement Watchdog battery backup system
can be installed. There are three systems with matching batteries that will provide
protection. The illustration below is an example of a typical battery backup
installation.
PUMP
WIRE
PIT COVER
CHECK
VALVE
F
LOAT
W
IRE
FLOAT
WIRE
MAIN
A/C PUMP
A
/C FLOAT
S
WITCH
BATTERY
BACKUP PUMP
BACKUP PUMP
FLOAT SWITCH
BATTERY
D
RAIN TILE
B
ATTERY
C
ABLE
AC
OUTLET
BACKUP SYSTEM
CONTROL UNIT
P
UMP
W
IRE
DUAL FLOAT CONTROLLER
PLUGGED INTO
AC OUTLET
SURGE
PROTECTOR
Visit our website www.basementwatchdog.com for more information about the
Basement Watchdog AC sump pumps and battery backup sump pump products.
Dual Float Controller
3
Warranty
GLENTRONICS, INC. warrants to the end purchaser that its pumps, switch and control unit products are free from defective materials and workmanship for the periods indicated below:
All parts and labor (excluding installation) for a period of:
• 3 years from the date of purchase on the 1/2 HP pump, when used intermittently as a sump pump
• 5 years from the date of purchase on the 3/4 HP pump, when used intermittently as a sump pump
• 1 year from the date of purchase on all pumps, when used in continuous duty operations such as fountains or ponds
The defective product must be returned directly to the factory, postage prepaid with the original bill of sale or receipt to the address listed below. GLENTRONICS, INC., at its option,
will either repair or replace the product and return it postage prepaid.
Conditions
The unit must be shipped, freight prepaid, or delivered to GLENTRONICS, INC. to provide the services described hereunder in either its original carton and inserts, or a similar package
affording an equal degree of protection.
The unit must not have been previously altered, repaired or serviced by anyone other than GLENTRONICS, INC., or its agent; the serial number on the unit must not have been altered
or removed; the unit must not have been subject to accident, misuse, abuse or operated contrary to the instructions contained in the accompanying manual.
The dealer's dated bill of sale, or installers invoice must be retained as evidence of the date of purchase and to establish warranty eligibility.
This warranty does not cover product problems resulting from handling liquids hotter than 104 degrees Fahrenheit, handling inflammable liquids, solvents, strong chemicals or severe
abrasive solutions; user abuse; misuse, neglect, improper maintenance, commercial or industrial use; improper connection or installation, damages caused by lightning strikes; excessive
surges in AC line voltage; water damage to the controller; other acts of nature, or failure to operate in accordance with the enclosed written instructions.
GLENTRONICS, INC. WILL NOT BE LIABLE FOR ANY INCIDENTAL, SPECIAL OR CONSEQUENTIAL DAMAGES FOR BREACH OF ANY EXPRESS OR IMPLIED WARRANTIES ON THIS PRODUCT. SOME
STATES DO NOT ALLOW FOR THE EXCLUSION OR LIMITATION OF CONSEQUENTIAL OR INDIRECT DAMAGE. THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THIS EXPRESS WARRANTY SHALL
BE EXCLUSIVE AND IS IN LIEU OF ALL OTHER WARRANTIES, WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO ANY WARRANTY OF MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. THIS CUSTOMER'S EXCLUSIVE REMEDY FOR BREACH OF THIS WARRANTY, OR OF ANY IMPLIED WARRANTY NOT EXCLUDED HEREIN, SHALL BE LIMITED TO
REPAIR OR REPLACEMENT OF THE PRODUCT.
For information or service contact:
Glentronics, Inc., 640 Heathrow Drive, Lincolnshire, IL 60069 800-991-0466
Model No. _________________________ Purchase Date _________________________