User manual
24
e) Storing Batteries ("STORAGE")
This rechargeable battery programme can be used if you want to store the
rechargeable battery for an extended period. Depending on the rechargeable
battery type set, the rechargeable battery is charged or discharged to a spe-
cic voltage.
Depending on the cell voltage, the battery is either charged or discharged. Of course, with a multi-cell bat-
tery pack, this is only wise if a balancer connection is available and connected to the charger.
At extended storage of a lithium rechargeable battery (e.g. when storing a ight battery over winter), the
rechargeable battery should in any case be checked every 3 months and treated with the rechargeable
battery programme "STORAGE" again to prevent harmful deep discharge.
The procedure when setting the cell number, battery capacity and current must be performed as in the rechargeable
battery programme "CHARGE" (chapter 11. b) or "BAL-CHG" (chapter 11. c).
The set current is used for charging/discharging.
LiPo STORAGE 3S
C= 3200mAh 2.0A