User manual

26
Charge a NiMH or NiCd battery as follows:
First, choose the rechargeable battery type with the button "STOP" or "–" as described in chapter 11. a) (NiMH or
NiCd) and push the button "START".
Select the rechargeable battery programme "CHARGE Man" with the but-
ton "+" or "–".
The value at the lower right represents the currently set charging current.
Use the button "+" or "–" to select a different rechargeable battery programme; use the button "STOP" to
return to the main menu.
If the value for the charging current must be changed, push the "START" button. The charging current ashes.
Change the charging current using the button "+" or "–". Keep the respective button pressed for quick adjustment.
The maximum possible charging current depends on the battery type and number of cells. The maximum
charging power is 80 W.
Conrm the set charging current with the "START" button.
When no display is ashing anymore, start charging by keeping the "START" button pushed (approx. 3 seconds).
The charger now examines the connected rechargeable battery. In case
of an error, a warning signal is output and the corresponding information is
displayed. You can stop the warning signal by pressing the "STOP" button.
You then return to the previous conguration menu.
If no error is found, e.g. the display shown on the right will appear.
The rechargeable battery type is shown in the upper left ("NiMH" = NiMH
rechargeable battery), the upper middle shows the charging current and the
upper right the current rechargeable battery voltage.
The lower left shows the current rechargeable battery programme ("CHG" = "CHARGE"), in the middle the elapsed
charging time and the charged capacity in mAh are displayed to the right of this.
After completion of charging, an audio signal is emitted (if it has not been turned off).
If you wish to cancel the charging process prematurely, push the button "STOP".
NiMH CHARGE Man
CURRENT 0.1A
NiMH 1.2A 7.6V
CHG 022:43 00682
BATTERY CHECK
PLEASE WAIT...