The maximum possible charging current depends on the battery type and number of cells. The maximum
charging power is 80 W.
Conrm the set charging current with the "START" button.
• The number of the cells in the lower right of the display ashes. Set the number of the cells with the buttons "+" and
"–". Keep the respective button pressed for quick adjustment.
Conrm the number of the cells by pressing the "START" button.
• When no display is ashing anymore, start charging by keeping the "START" button pushed (approx. 3 seconds).
• The charger now examines the connected rechargeable battery. In case
of an error, a warning signal is output and the corresponding information is
displayed. You can stop the warning signal by pressing the "STOP" button.
You then return to the previous conguration menu.
• Charging begins. The display will show various information on the current
charging progress.
At the upper left, the rechargeable battery type and the cell number are
displayed ("Pb6" = lead battery with 6 cells); the charging current is shown
in the upper middle and the current rechargeable battery voltage at the
upper right.
The lower left shows the current rechargeable battery programme ("CHG" = "CHARGE"), in the middle the elapsed
charging time and the charged capacity in mAh are displayed to the right of this.
Various information is indicated on the display during a charge/discharge process by repeatedly pressing
the button "–" (see chapter 20). If you do not push any button for a few seconds, the charger will return to
the normal display.
• After completion of charging, an audio signal is emitted (if it has not been turned off).
If you wish to cancel the charging process prematurely, push the button "STOP".
BATTERY CHECK
PLEASE WAIT...
Pb6 1.0A 12.3V
CHG 022:45 00690