b) Loading Battery Data
• Select the function "Memory Load" in the main menu of the charger with the
button "STOP" or "–".
• Conrm the selection by pressing the "START" button.
• Select one of the 10 memories (01....10) with the button "+" or "–".
The data stored in the memory are displayed, e.g. rechargeable battery
type, rechargeable battery programme, cell number, charging and discharg-
ing current.
• Load the battery data from the selected memory by pushing the button "START" briey.
• The charger is then in the corresponding rechargeable battery programme, and the associated data are displayed.
In the example on the right, the data for a LiPo rechargeable battery with
3 cells, a capacity of 3000 mAh and a charge current of 3.0 A have been
transferred from the memory.
• The rechargeable battery programme can be started as usual by pushing the "START" button for 3 seconds.
Alternatively you can, of course, change the settings loaded from the memory, e.g. to increase or reduce
the charging current.
Briey push the "START" button several times; the respective chosen set value ashes.
Change the set value using the button "+" or "–". Keep the respective button pressed for quick adjustment.
Briey push the "START" button to accept the setting.
When no display is ashing anymore, keep the "START" button pushed (approx. 3 seconds), to start the
rechargeable battery programme.
PROGRAM SELECT
Memory Load
MEMORY LiPo [01]
BAL 3S 1.0A
LiPo BAL-CHG 3S
C= 3000mAh 3.0A