User manual
38
Max. cell voltage when charging
The maximum cell voltage can be set depending on the set rechargeable bat-
tery type (LiPo, LiIon, LiFe, LiHv and Pb).
The charger ends charging when all cells have reached the set voltage.
LiPo: 3.80 - 4.20 V/cell (basic setting 4.20 V)
LiIon: 3.80 - 4.10 V/cell (basic setting 4.10 V)
LiFe: 3.30 - 3.65 V/cell (basic setting 3.60 V)
LiHv: 4.00 - 4.40 V/cell (basic setting 4.35 V)
Pb: 2.10 - 2.50 V/cell (basic setting 2.40 V)
Loading factory settings (reset)
This recovers the factory settings (reset).
Keep the button "START" pressed for more than 2 seconds.
Then the charger starts again and will then be in the main menu again.
Observe that all values set by you are then reset to factory settings; the 10 rechargeable battery memories
(see chapter 14) are also deleted.
Battery end volt
LiPo 4.20V/C
Battery end volt
LiIo 4.10V/C
Battery end volt
LiFe 3.60V/C
Battery end volt
LiHV 4.35V/C
Battery end volt
Pb 2.40V/P
FACTORY RESET
PRESS ENTER >2S