User manual
39
16. Fixed Voltage Output
The charger offers the option of using the charging output (the two 4 mm output sockets) like a conventional control-
lable mains unit.
In this case, the charger supplies a direct voltage to the output sockets; setting of 5.0 V/DC to 24.0 V/DC is possible.
The output current can be set to between 0.1 A and 10.0 A. Observe that the maximum output current is not possible
for the maximum current; the charger can only supply 80 W at most.
Caution, important!
If this function is used, never connect a rechargeable battery to the two output sockets of the charger.
Before you activate this function and set an output voltage and an output current, always disconnect any
connected rechargeable battery from the charger.
There is a risk of re and explosion!
Proceed as follows:
• Disconnect any connected rechargeable battery from the charger rst (both from the 4 mm output sockets and the
balancer connection).
• The charger must be in the main menu. Select the "Digital Power" function
with the "STOP" or "–" button here, see gure on the right.
• Conrm the selection by pressing the "START" button.
• The display shows "POWER MODE". The set output current type is shown
in the lower left of the display, and the output voltage to its right.
• To change the output current and the output voltage, briey push the
"START" button. The value of the output current starts to ash.
• Change the output current using the button "+" or "–". Keep the respective button pressed for quick adjustment.
• Briey push the "START" button; the output voltage ashes.
• Change the output voltage using the button "+" or "–". Keep the respective button pressed for quick adjustment.
• Briey push the button "START"; the display will stop ashing.
• Keep the "START" button depressed (approx. 3 seconds). The charger activates the xed voltage output. A signal
will be sounded (if it has not been switched off in the setting menu). The fan starts to run.
The display shows the current intake ("CURRENT") and output voltage
("VOLTAGE") at the moment.
Slight uctuations in the display of voltage/current are normal
(measuring-technically caused). For this reason, a (low) output cur-
rent will be displayed even when nothing is connected to the output
as well.
• To set the output current and the output voltage, briey push the "START" button.
Caution, important!
A connected consumer can be damaged when changing the output voltage.
Therefore, disconnect the connected consumer from the output sockets of the charger before changing the
output voltage.
The same applies, if applicable, when changing the output current.
PROGRAM SELECT
Digital Power
POWER MODE
1.0A 12.0V
CURRENT 0.52A
VOLTAGE 12.0V