User manual

41
17. Voltage Display for Lithium Rechargeable Batteries
The charger can also display the current voltages of the cells of a lithium rechargeable battery.
For this, the rechargeable lithium battery must have a balancer connection that must be connected to the
charger.
Proceed as follows:
Select the function "Battery Meter" in the main menu of the charger with the
buttons "STOP" or "–".
Conrm the selection by pressing the "START" button.
Then the voltage display appears.
Use the buttons "+" or "–" to switch between:
- Individual voltages of cells 1 - 6
- Input voltage and voltage at the two rechargeable battery connections
- Internal temperature of the charger and temperature of the external sensor (not enclosed, can be ordered
separately)
The individual voltage displays depending on the cell number, of course. The example gure may be a
3-cell LiPo rechargeable battery (or a multiple-cell LiPo rechargeable battery with defective cells or defec-
tive balancer connections).
If the charger is operated via the mains voltage, the input voltage is always displayed as 15 V/DC (this is
the voltage of the internal mains unit).
Slight uctuations of the voltage display are normal (measuring-technically caused).
For "OUTPUT", the voltage pending at the charging sockets is displayed (if a rechargeable battery is con-
nected).
You can return to the main menu as usual via the "STOP" button.
PROGRAM SELECT
Battery Meter
1:4.19 4.17 4.19
4:0.00 0.00 0.00
OUTPUT: 12.46V
INPUT : 15.00V