User manual
41
17. Voltage Display for Lithium Rechargeable Batteries
The charger can also display the current voltages of the cells of a lithium rechargeable battery.
For this, the rechargeable lithium battery must have a balancer connection that must be connected to the
charger.
Proceed as follows:
• Select the function "Battery Meter" in the main menu of the charger with the
buttons "STOP" or "–".
• Conrm the selection by pressing the "START" button.
• Then the voltage display appears.
• Use the buttons "+" or "–" to switch between:
- Individual voltages of cells 1 - 6
- Input voltage and voltage at the two rechargeable battery connections
- Internal temperature of the charger and temperature of the external sensor (not enclosed, can be ordered
separately)
The individual voltage displays depending on the cell number, of course. The example gure may be a
3-cell LiPo rechargeable battery (or a multiple-cell LiPo rechargeable battery with defective cells or defec-
tive balancer connections).
If the charger is operated via the mains voltage, the input voltage is always displayed as 15 V/DC (this is
the voltage of the internal mains unit).
Slight uctuations of the voltage display are normal (measuring-technically caused).
For "OUTPUT", the voltage pending at the charging sockets is displayed (if a rechargeable battery is con-
nected).
• You can return to the main menu as usual via the "STOP" button.
PROGRAM SELECT
Battery Meter
1:4.19 4.17 4.19
4:0.00 0.00 0.00
OUTPUT: 12.46V
INPUT : 15.00V