User manual

43
19. Warning Messages on the Display
REVERSE POLARITY
CONNECTION BREAK
SHORT ERROR
INPUT VOL ERR
BATTERY CHECK
LOW VOLTAGE
BATTERY CHECK
HIGH VOLTAGE
BATTERY VOLTAGE
CELL LOW VOL
BATTERY VOLTAGE
CELL HIGH VOL
BATTERY VOL ERR
CELL CONNECT
TEMP OVER ERR
The polarity of the rechargeable battery connections has been switched.
The connection to the rechargeable battery has been disrupted, e.g. if the
battery has been disconnected during the charging process.
There is a short circuit at the output of the charger.
A problem has been identied at the direct voltage input of the charger.
The rechargeable battery voltage is too low. Check the setting of the re-
chargeable battery type and the cell number at the charger.
The rechargeable battery voltage is too high. Check the setting of the re-
chargeable battery type and the cell number at the charger.
The voltage of a cell of a connected lithium rechargeable battery is too low (a
cell may be defective or deep-discharged).
The voltage of a cell of a connected lithium rechargeable battery is too high
(possibly overloaded or balancer connection defective).
There is a problem with the balancer connection (balancer plug not connected
or defective).
The inner temperature of the charger is too high. Let the charger cool off.