23. Technical Data
Operating voltage ........................................ Mains voltage input: 100 - 240 V/AC, 50/60Hz
Direct voltage input: 11 - 18 V/DC
Never use both inputs at the same time. This may damage the charger. Loss of guarantee/warranty!
Charging/discharging channels ................... 1
Charge current ............................................. 0.1 - 10.0 A (depending on the cell number and rechargeable battery
type)
Charging output ........................................... max. 80 W
Discharge current ........................................ 0.1 - 2.0 A (depending on the cell number and rechargeable battery
type)
Discharge output ......................................... max. 5 W
Suitable rechargeable batteries ................... NiMH/NiCd, 1 - 15 cells
LiPo/LiIon/LiFe/LiHv, 1 - 6 cells
Pb, 1 - 10 cells (rated voltage 2 - 20 V)
Discharge current for balancer .................... 400 mA per cell
Delta-U-recognition ...................................... yes (for NiMH/NiCd, adjustable 5 - 20 mV/cell)
Maintenance charge current ........................ yes (for NiMH/NiCd, adjustable 50 - 200 mA, can be switched off)
Safety timer ................................................. yes (10 - 720 minutes, can be switched off)
Fan integrated ............................................. yes
Ambient conditions ...................................... Temperature +10 °C to +40 °C; humidity 0% to 90% relative, non-
condensing
Weight ......................................................... 396 g
Dimensions .................................................. 130 x 115 x 61 mm (W x D x H)