User`s manual

Color Creation and Enhancement
Basler ace Camera Link 133
Enabling and Setting Gamma Correction Using Direct Register Access
To enable gamma correction and to set the gamma value via direct register access:
Set the value of the Gamma Enable register to Enabled.
Set the value of the Gamma Selector register to SRGB or User.
If the Gamma Selector is set to User, eet the value in the Gamma register to the desired
gamma value.
For more information about direct register access, see Section 3.2 on page 19.