User`s manual

Features
Basler ace Camera Link 217
10.14.1 Selecting a Factory Setup as the
Default Set
When the camera is delivered, the Auto Functions Factory Setup will be selected as the default set.
You can, however, select any one of the three factory setups to serve as the default set.
Selecting a Factory Setup Using pylon
To select which factory setup will serve as the default set using Basler pylon:
Set the Default Set Selector to the Standard Factory Setup, High Gain Factory Setup or Auto
Functions Factory Setup.
You can set the Default Set Selector from within your application software by using the pylon API.
The following code snippet illustrates using the API to set the selector:
If you want to select the Standard Factory Setup:
Camera.DefaultSetSelector.SetValue(DefaultSetSelector_Standard);
If you want to select the High Gain Factory Setup:
Camera.DefaultSetSelector.SetValue(DefaultSetSelector_HighGain);
If you want to select the Auto Functions Factory Setup:
Camera.DefaultSetSelector.SetValue(DefaultSetSelector_AutoFunctions);
If you want to select the Color Factory Setup:
Camera.DefaultSetSelector.SetValue(DefaultSetSelector_Color);
Selecting a Factory Setup Using Direct Register Access
To select which factory setup will serve as the default set via direct register access:
Set the Default Set Selector register to the Standard Factory Setup, High Gain Factory Setup,
Auto Functions Factory Setup, or Color setup.
Selecting which factory setup will serve as the default set is only allowed when the
camera is idle, i.e. when it is not acquiring images continuously or does not have
a single image acquisition pending.
Selecting the standard factory setup as the default set and then loading the default
set into the active set is a good course of action if you have grossly misadjusted
the settings in the camera and you are not sure how to recover. The standard
factory setup is optimized for use in typical situations and will provide good camera
performance in most cases.