User`s manual
Smart Features
6-14 BASLER A620
f
DRAFT
DCAM Values Chunk Layout
Position Name Description
0 Gain CSR
[ 4 Bytes ]
Content of the DCAM Gain CSR
Field Bit Description
Presence Inq 0 Presence of this feature
If 0, the DCAM feature is not avail-
able and all of its values should be 
ignored
Abs Control 1 Absolute control mode
If 1, the DCAM feature is in absolute 
control mode and the current value 
can be read from the Absolute Value 
CSR. Otherwise, the Value field 
holds the current raw value setting.
----- 2 ... 4 reserved
One Push 5 If 1, a one push operation was in 
progress.
ON OFF 6 0: The feature was disabled, ignore 
the value
1: The feature was enabled
A/M Mode 7 0: The feature was in manual control 
mode
1: The feature was in auto control 
mode
-- 8 ... 19 Reserved
Value 20 ... 31 Value of the feature
4 Gain Absolute Value 
CSR
[ 4 Bytes ]
Field Bit Description
Abs Value 0 ... 31 Floating point value with 
IEEE/real*4 format
Unit: dB
8 Shutter CSR
[ 4 bytes ]
Content of the DCAM Shutter CSR
Same layout as the GAIN CSR
12 Shutter Absolute Value 
CSR
[ 4 Bytes ]
Field Bit Description
Abs Value 0 ... 31 Floating point value with 
IEEE/real*4 format
Unit: seconds
16 Gamma CSR
[ 4 bytes ]
Content of the DCAM Gamma CSR
Same layout as the Gain CSR
20 Gamma Absolute Value 
CSR
[ 4 Bytes ]
Field Bit Description
Abs Value 0 ... 31 Floating point value with 
IEEE/real*4 format
Unit: dB