Register Name: Software Trigger 
Offset from Base Address: 0x62C
Field Bit Description
Trigger
0 When the Trigger Source field of the Trigger Mode register (see page 
4-26) is set for a software trigger, this field controls the software trigger.
0 = reset the software trigger
1 = set the software trigger
(If the Trigger Mode field of the Trigger Mode register is set to 0, this 
field will self clear.)
---
1 ... 31 Reserved
Register Name: Data Depth
Offset from Base Address: 0x630
Field Bit Description
Depth 0 ... 7 Indicates the effective depth of the data in the transmitted images.
Depends on the current format and mode settings. Also depends on 
the Color Coding ID if the camera is set for Format 7.
This field is read only.
Camera set for: Effective data depth indicated:
Mono 8 output 8 bits/pixel
Mono 16 output 10 bits/pixel
---