4.4.2.2 Control and Status Registers for Features
Register Name: Brightness 
Offset from Base Address: 0x800
Field Bit Description
Presence Inq 0 Indicates the presence of the brightness control feature.
The value will be 1 on all A620f cameras, indicating that brightness 
control is available.
This field is read only.
Abs Control
1 Determines whether the brightness will be controlled by the Value field 
of this register or by the Absolute Value CSR for brightness.
The value will be 0, indicating that brightness can only be controlled by 
the Value field of this register. Absolute value control is not available 
on A620f cameras.
This field is read only.
---
2 ... 4 Reserved
One Push 5 Sets “One Push” operation.
The value will be 0, indicating that one push is not in operation. One 
push operation is not available on A620f cameras.
This field is read only.
On / Off
6 Sets whether brightness control is on or off.
The value will be 1, indicating that brightness control is on. The bright-
ness control feature can’t be switched off on A620f cameras.
This field is read only.
A / M Mode
7 Sets whether the camera is in automatic or manual brightness control 
mode.
The value will be 0, indicating that brightness control is in manual 
mode. Automatic brightness control is not available on A620f cameras.
This field is read only.
--- 8 ... 19 Reserved
Value 20 ... 31 Sets the brightness. The brightness value can range from 0 to 255.
Default = 8
The effect of a change in the brightness value varies depending on 
whether the camera is set to output 8 bits per pixel or 16 bits per pixel. 
When the camera is set for 8 bit output, increasing the brightness value 
by 4 results in an increase of 1 in the digital values output by the cam-
era. When the camera is set for 16 bit output, increasing the brightness 
value by 1 results in a increase of 1 in the digital values output by the 
camera.