User`s manual
AW00098504000 Features 
Basler ace Camera Link 173
signal and set Control B as disabled. In this case, you could point to sequence parameter set 0 or 
sequence parameter set 1 by simply using CC1 to set the state of Control A.
Populating the Sequence Parameter Sets
Before you begin using the sequencer feature, you must populate the sequence sets with values 
that will be useful for your particular situation. You should use the following procedure to populate 
the sequence sets:
 Make sure that the sequencer feature is disabled.
 Set up your first acquisition scenario (i.e., lighting, object positioning, etc.).
 Adjust the camera parameters to get the best image quality with this scenario (you are 
adjusting the parameters in the active set).
 Use the Sequence Set Selector to select sequence set 0, 1, 2, or 3.
 Execute the Sequence Set Store command to copy the sequence parameter values currently 
in the active set into the selected sequence set. (Any existing parameter values in the 
sequence set will be overwritten.)
 Repeat the above steps for the other sequence sets.
There is also a command called Sequence Set Load that can be useful when working with the 
sequence parameter sets. If you use the Sequence Set Selector parameter to select a sequence 
set and then you execute the Sequence Set Load command, the sequence parameter values in the 
active set will be replaced by the values stored in the selected sequence set. This ability can be 
useful in two situations. First, if you simply want to see how the parameters currently stored in one 
of the sequence parameter sets will affect camera operation, you can load the parameters from that 
sequence parameter set into the active parameter set and see what happens. Second, if you want 
to prepare a new sequence parameter set and you know that an existing set is already close to what 
you will need, you can load the existing sequence set into the active set, make some small changes 
to the active set, and then save the active set to one of the other sequence parameter sets.
Replacing the sequence parameter values in the active set via the Sequence Set 
Load command is much slower than by involving the Controls A and B. We 
therefore recommend to only use the Controls A and B for acquiring images 
continuously.
Because the sequence parameter sets reside in volatile memory, they are not 
retained if camera power is switched off.