User`s manual
Features  AW00098504000
218 Basler ace Camera Link
User Sets
As mentioned above, the active configuration set is stored in the camera’s volatile memory and the 
settings are lost if the camera is reset or if power is switched off. The camera can save most of the 
settings from the current active set to a reserved area in the camera’s non-volatile memory. A 
configuration set that has been saved in the non-volatile memory is not lost when the camera is 
reset or switched off. There are three reserved areas in the camera’s non-volatile memory available 
for saving configuration sets. A configuration set saved in a reserved area is commonly referred to 
as a "user set".
The three available user sets are called User Set 1, User Set 2, and User Set 3.
When the camera is running, a saved user set can be loaded into the active set. A saved user set 
can also be designated as the "startup" set, i.e., the set that will be loaded into the active set 
whenever the camera is powered on or reset. Instructions for loading a saved user set into the 
active set and for designating which set will be the startup set appear later in the Configuration Sets 
section.
Designating a Startup Set 
You can designate the default set or one of the user sets as the "startup" set. The designated startup 
set will automatically be loaded into the active set whenever the camera starts up at power on or 
after a reset. Instructions for designating the startup set appear below.
The values for the luminance lookup table are not saved in the user sets and are 
lost when the camera is reset or switched off. If you are using the lookup table 
feature, you must reenter the lookup table values after each camera startup or 
reset.