User`s manual
AW00098504000 Physical Interface 
Basler ace Camera Link 39
5.7.2.3 Response Time
The response times for the GPIO line on the camera when the line is set to operate as an input are 
as shown in Figure 12.
Time Delay Rise (TDR) = 1.3 µs to 1.6 µs
Time Delay Fall (TDF) = 40 µs to 60 µs
Level of
Camera’s
Internal Input
Circuit
Voltage Applied 
to the Camera’s 
Input Line
Time
TDR
TDF
2.2 V
(10.4 V with PLC cable)
1.4 V
(8.4 V with PLC cable)
Not to Scale
Fig. 12: GPIO Line Input Response Times