User`s manual
AW00098504000 Image Acquisition Control 
Basler ace Camera Link 69
7.2 The Acquisition Start Trigger
(When reading this section, it is helpful to refer to Figure 20 on page 67.)
The acquisition start trigger is used in conjunction with the frame start trigger to control the 
acquisition of frames. In essence, the acquisition start trigger is used as an enabler for the frame 
start trigger. Acquisition start trigger signals can be generated within the camera or may be applied 
externally as software or hardware acquisition start trigger signals.
When the acquisition start trigger is enabled, the camera’s initial acquisition status is "waiting for 
acquisition start trigger". When the camera is in this acquisition status, it will ignore any frame start 
trigger signals it receives. If an acquisition start trigger signal is applied to the camera, it will exit the 
"waiting for acquisition start trigger" acquisition status and enter the "waiting for frame start trigger" 
acquisition status. In this acquisition status, the camera can react to frame start trigger signals and 
will begin to expose a frame each time a proper frame start trigger signal is applied. 
A primary feature of the acquisition start trigger is that after an acquisition start trigger signal has 
been applied to the camera and the camera has entered the "waiting for frame start trigger" 
acquisition status, the camera will return to the "waiting for acquisition start trigger" acquisition 
status once a specified number of frame start triggers has been received. Before more frames can 
be acquired, a new acquisition start trigger signal must be applied to the camera to exit it from 
"waiting for acquisition start trigger" status. Note that this feature only applies when the Trigger 
Mode parameter for the acquisition start trigger is set to on. This feature is explained in greater 
detail in the following sections.
7.2.1 Acquisition Start Trigger Mode
The main parameter associated with the acquisition start trigger is the Trigger Mode parameter. The 
Trigger Mode parameter for the acquisition start trigger has two available settings: off and on. 
7.2.1.1 Acquisition Start Trigger Mode = Off
When the Trigger Mode parameter for the acquisition start trigger is set to off, the camera will 
generate all required acquisition start trigger signals internally, and you do not need to apply 
acquisition start trigger signals to the camera.
7.2.1.2 Acquisition Start Trigger Mode = On
When the Trigger Mode parameter for the acquisition start trigger is set to on, the camera will initially 
be in a "waiting for acquisition start trigger" acquisition status and cannot react to frame start trigger 
signals. You must apply an acquisition start trigger signal to the camera to exit the camera from the 
"waiting for acquisition start trigger" acquisition status and enter the "waiting for frame start trigger" 
acquisition status. The camera can then react to frame start trigger signals and will continue to do 
so until the number of frame start trigger signals it has received is equal to the current Acquisition 