Formula 1:
Calculates the maximum frame rate based on the sensor readout time:
Where:
AOI Height = the height of the acquired frames as determined by the AOI settings.
The constants C
1
and C
2
depend on the camera model as shown in the table below:
* Note: The maximum frame rate of the piA1900-32gm/gc is limited to 32 fps.
Formula 2:
Calculates the maximum frame rate based on the exposure time for the acquired frames:
Where:
The constant C
3
depends on the camera model as shown in the table below:
C
1
C
2
piA640-210gm/gc 8.76 µs 521.17 µs
piA1000-48gm/gc 13.39 µs 7423.76 µs
piA1600-35gm/gc 20.52 µs 3873.2 µs
piA1900-32gm/gc* 0 µs 31021.26 µs
piA2400-12gm/gc 26.18 µs 26001.76 µs
C
3
piA640-210gm/gc 46.99 µs
piA1000-48gm/gc 95.57 µs
piA1600-35gm/gc 79.64 µs
piA1900-32gm/gc 139.38 µs
piA2400-12gm/gc 76.80 µs
Max. Frames/s
1
AOI Height C
1
×[]C
2
+
---------------------------------------------------------------=
Max. Frames/s
1
Exposure time in µs C
3
+
------------------------------------------------------------------=