Product Overview
G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve Product Bulletin 5
Ordering Information
• Define the G196 model number using the ordering
matrix shown in Figure 6. When ordering, include
information regarding the following specifications:
• regulator setting (in. W.C. [mbar/kPa] at specific
flow)
• type of gas (natural or LP)
• type of ignition system (intermittent pilot or direct)
• optional features
Inlet/Outlet
G1 96
_ _
-
__
A=
G=
Customer-specific Requirements
1/2 x 1/2 in. NPT
1/2 x 3/4 in. NPT
1/2 x 3/8 in. NPT
_
Letter
Natural Gas
Capacity @ 1 in. W.C.
(2.5 mbar [0.25 kPa])
Pressure Drop
kWBtu/hr
51
51
45
175,000
175,000
155,000
Letter
Voltage
120 VAC, 60 Hz
25 VAC, 60 Hz
Letter
A
C
H
K
=
=
=
=
Regulator Type
Top Adjust: 3 to 6 in. W.C. (7.5 to 15 mbar [0.75 to 1.5 kPa])
Top Adjust: 6 to 12 in. W.C. (15 to 30 mbar [1.5 to 3.0 kPa])
Bottom Adjust: 3 to 6 in. W.C. (7.5 to 15 mbar [0.75 to 1.5 kPa])
Bottom Adjust: 8 to 12 in. W.C. (20 to 30 mbar [2.0 to 3.0 kPa])
The presence of a particular construction ins this information does not guarantee
its availability. Consult Johnson Controls for available constructions.
H =
J =
N =
Figure 6: Ordering Matrix