Manual

BatteryMINDer
©
Model 12248-A-ODY
Rev. D-050509 Page 22 P/N VDC12248-A-ODY-MNL
be so large it may require a second full recharge. Repeat
recharge. 3. If recharging multiple batteries, 2 or more
complete recharge cycles may be needed. Repeat full
recharge. If still RED - blinking, you may need to charge
each battery separately.
Problem:
Battery Condition Indicator lights Yellow (After battery
has been completely charged)
Solution:
Battery still has an unacceptable level of sulphation and must
stay connected to charger and remain in Maintenance-Float
mode (GREEN blinking indicator) for 72 hours or longer. Then
stop charger by pressing STOP/RESTART button and observe
Indicator. If still Yellow repeat (up to 3 full cycles) or until
indicator lights GREEN.
Problem:
Battery Condition Indicator lights Yellow (May be several
causes) (Before battery is completely charged)
Solution.
Battery can be weak due to sulphation, self discharge or was
very deeply discharged. Attempt a full recharge and recheck
after completion. If still Yellow follow procedure for (After
battery has been completely charged.)
Problem.
Charger Indicators show battery is fully charged, but fails to
provide good cranking, lighting or equipment run time, as it did
when newer.
Solution.
Battery may be defective. Have it tested by a qualified source.