Dimensional Data Fan Installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING: (a) Use this unit only in the manner intended by the manufacturer. If you have any questions contact the manufacturer. (b) Before servicing or cleaning the unit, switch the power off at the service panel and lock the service disconnecting means to prevent power from being switched on accidentally.
Select Fan Location When selecting a location to install the Dragon fan, take into consideration the application of the product, the locations of fresh air intakes, and sound generated by the Dragon unit. If ductwork is to be used, consider the path of the ducting material. The fan should be located a minimum of 6 feet horizontally and 8 feet vertically from any fresh air intakes for HVAC systems, heat recovery systems, etc. to prevent exhaust air streams from being re-introduced into the occupied space.
buildings codes. Note: A licensed Electrician may be needed. If unsure, consult with your local Electrical Inspector. WIRING INSTRUCTIONS WARNING! Make sure that power supply is disconnected and locked to prevent accidental activation. 1. Remove the screws securing the terminal box cover plate located on the fan motor mounting bracket. All fan motor and capacitor connections are pre-wired to the electrical terminal strip.
WIRING DIAGRAMS 4
LIMITED WARRANTY If, within the period of three years from the date of purchase, the Dragon (the Product) is defective or malfunctions in normal home use, Tamarack Technologies, Inc. will repair or replace the Product at its discretion without charge for labor or materials. Customer is responsible for shipping charges.