Manual and Installation Guide BB10012
Charging Parameters Bulk/Absorption For your Bulk/Absorption stage, the ideal voltage is between 14.2v-14.6v. For full charge and balance, the absorption mode should be set to last for at least 20 minutes per battery (for multiple batteries in parallel). Float Our batteries do not need a float stage for charging, but a float voltage between 13.4V and 13.8V can be used when connected to shore power. Equalization Equalization is not recommended for our batteries.
BMS Basic Features All Battle Born Batteries come with a built-in battery management system (BMS) that protects the cells for long-term cycling. The BMS protects against the following conditions: High voltage: > 14.7V If an individual cell voltage exceeds a prescribed threshold during charging, the BMS will prevent a charge current from continuing. Discharge is always allowed under this condition.
Installation The batteries may be mounted in any orientation. But care must be taken in connecting to the battery terminals. The positive and negative terminals are labeled and color coded (red for +, black for -). DO NOT REVERSE POLARITY THE BATTERY AS THIS WILL DAMAGE BOTH THE BATTERY AND THE DEVICE BEING CONNECTED!!! The batteries come standard with a flag style terminal post with a 3/8” hole to accommodate a 5/16” bolt and lug sizes up to 2 AWT. Larger lugs may require a 1/4" bolt.
600A for 30 seconds. Therefore, all cables and connections MUST be able to accommodate the high currents that can be delivered by the battery. Appropriate fuses and circuit breakers are also highly recommended to protect downstream components from current spikes and short circuits. Series Up to four BB10012 batteries may be connected in series to increase the voltage of the system up to a 48V system.
Storage and maintenance Storage Storage could not be easier simply charge the batteries to at least 50% state-of-charge and disconnect from any charge or discharge. Maintenance Battle Born Batteries require very little maintenance if any at all. If your batteries are in series and not being charged by a multi-bank charger it is recommended that you fully charge the batteries individually once a year. This will balance out the entire battery bank to ensure the batteries will reach its expected life span.
Warranty Policy In the unlikely event, you are having an issue with one of our batteries we have developed a straight forward warranty policy to help answer any questions you may have. Battle Born Batteries offers a 10-year manufacturers defect warranty from the date of purchase (see attached Warranty) We also warrant all other complimentary products (inverters, converters, chargers etc) we sell are free from defect for 30 days from the date of purchase.
Return & Refund Policy Thanks for shopping at Battle Born Batteries. If you are not entirely satisfied with your purchase, we're here to help. Returns You have 45 calendar days to return an item from the date the item shipped. To be eligible for a return, your item must be in the same condition that you received it in. Keep the original packaging for 45 days. Your item must be in the original packaging. Your item needs to have the receipt or proof of purchase.
Contact Us If you have any further questions, or need help with anything regarding your battery please do not hesitate to contact us. Battle Born Batteries Address 4814 Longley Ln Reno, NV 89502 Email info@battlebornbatteries.