Dekker Vacuum Technologies, Inc. DuraVane/12 20
2. Check if motor rotation is correct by comparing it to the arrow on the motor or pump housing. If incorrect
switch any two of the three main power leads on the contactor (3-phase only).
3. Check bearings. If bearings are noisy, contact authorized dealer for replacement instructions.
4. Foreign particles may have carried over into the pump, causing damage to the vanes or other internal parts.
Contact authorized dealer.
5. One of the vanes in the rotor may be stuck. Contact authorized dealer for instructions.
HIGH OIL-CONSUMPTION PROBLEMS
Unit has abnormally high oil-consumption: (DuraVane Lubricated)
1. Stop unit and disconnect power.
2. Check around pump for oil leaks. Oil tubing may be damaged or defective. Replace if necessary.
3. Abnormal oil consumption could be the result of smoking problems at the exhaust side (see above).