inimum flow adjustment for hob gas taps.
egistered
IMPORTANT: Always isolate the hob from the electricity supply
anging the injectors and/or adjusting the minimum
flow of the burners.
o Switch the burner
on and set the
knob at the
o e knob
ap and
place a small
ap
der to increase the gas flow
or tighten the adjusting screw to decrease the gas flow.
tly
o Make sure that the flame does not go out by quickly turning
minimum flow. If it does then remove
the control knob and make further adjustments to the gas
o
M
All work must be carried out by a CORGI r
engineer.
before ch
minimum
position.
Remove th
from the t
bladed
screwdriver in the
centre of the t
shaft.
o Unscrew the adjusting screw, in or
o The correct adjustment is obtained when the flame has a
length of about 3 – 4 mm.
o For butane/propane gas, the adjusting screw must be tigh
screwed in.
o Refit the control knob.
from maximum flow to
flow, testing it again once the adjustment has been made.
Repeat this process for each one of the gas taps.